ÖÐÎÄ
¶Ë¿Ú¸»ºñ£¬ËÙÂÊÉý¼¶£¬ÊµÏÖÈõµçÏäÄÚǶװÖÃÉè¼Æ£¬ÍƼöÓÃÓÚÊÒÄÚ£¬ÑŹÛÇÒÇå¾²
ÀàÐÍ£º
16¿ÚPoEǧÕ×µç,2¿ÚPoEÍòÕ×µç,2¿ÚÍòÕ×¹â,PoE++
8¿ÚǧÕ׵磬2¿ÚÍòÕ׵磬2¿ÚÍòÕ׹⣬PoE++
8¿ÚǧÕ׵磬2¿Ú2.5Gµç£¬2¿ÚÍòÕ×¹â
8¿ÚǧÕ׵磬2¿Ú5Gµç£¬2¿ÚÍòÕ׹⣬PoE+
8¿ÚǧÕ׵磬4¿ÚÍòÕ×¹â
16¿ÚǧÕ׵磬2¿ÚǧÕ×¹â
16¿ÚǧÕ׵磬2¿ÚǧÕ׹⣬PoE+
16¿ÚǧÕ×µç,2¿Ú2.5Gµç,2¿ÚÍòÕ×¹â
16¿ÚǧÕ׵磬2¿Ú5Gµç£¬2¿ÚÍòÕ׹⣬PoE+
²úÆ·ÌØÕ÷£º
¶àÐÎ̬¹Ò¶úÊÊÅä²î±ðÇéÐΣ¬Ð¡»úÉíÖ§³ÖÄÚǶʽÈõµçÏä×°Öã¬×Àµ××°Ö㬶¨ÖÆ»ú¹ñ×°Öõȣ¬ÎÞа°²ÅÅ
| ½Ó¿Ú¹æ¸ñ | RG-SF2920-8GT4XS | RG-SF2920-8GT2MG2XS | RG-SF2920-16GT2SFP | RG-SF2920-16GT2MG2XS |
| ¹Ì»¯ÓªÒµ½Ó¿Ú | 8¸ö10/100/1000M×Ô˳Ӧµç¿Ú 4¸ö1G/2.5G/10G SFP+¹â¿Ú |
8¸ö10/100/1000M×Ô˳Ӧµç¿Ú 2¸ö1G/2.5G×Ô˳Ӧ¿Ú 2¸ö1G/10G SFP+¹â¿Ú |
16¸ö10/100/1000M×Ô˳Ӧµç¿Ú 2¸ö1G SFP¹â¿Ú |
16¸ö10/100/1000M×Ô˳Ӧµç¿Ú 2¸ö1G/2.5G×Ô˳Ӧ¿Ú 2¸ö1G/10G SFP+¹â¿Ú |
| ½Ó¿Ú¹æ¸ñ | RG-SF2920-8GT2MG2XS-P | RG-SF2920-8GT2XMG2XS-P | RG-SF2920-16GT2SFP-P | RG-SF2920-16GT2MG2XS-P |
| ¹Ì»¯ÓªÒµ½Ó¿Ú | 8¸ö10/100/1000M×Ô˳Ӧµç¿Ú 2¸ö1G/2.5G/5G×Ô˳Ӧµç¿Ú 2¸ö1G/10G SFP+¹â¿Ú |
8¸ö10/100/1000M×Ô˳Ӧµç¿Ú 2¸ö1G/2.5G/5G/10G×Ô˳Ӧ¿Ú 2¸ö1G/2.5G/10G SFP+¹â¿Ú |
16¸ö10/100/1000M×Ô˳Ӧµç¿Ú 2¸ö1G SFP¹â¿Ú |
16¸ö10/100/1000M×Ô˳Ӧµç¿Ú 2¸ö1G/2.5G/5G×Ô˳Ӧµç¿Ú 2¸ö1G/10G SFP+¹â¿Ú |
| ½Ó¿Ú¹æ¸ñ | RG-SF2920-16GT2XMG2XS-UP |
| ¹Ì»¯ÓªÒµ½Ó¿Ú | 16¸ö10/100/1000M×Ô˳Ӧµç¿Ú 2¸ö1G/2.5G/5G/10G×Ô˳Ӧµç¿Ú 2¸ö1G/2.5G/10G SFP+¹â¿Ú£¨2.5GÊÊÅäÇë²Î¿¼Ó²¼þ×°ÖÃÊֲᣩ |
| ϵͳ¹æ¸ñ | RG-SF2920-8GT4XS | RG-SF2920-8GT2MG2XS | RG-SF2920-16GT2SFP | RG-SF2920-16GT2MG2XS |
| ½»Á÷ÈÝÁ¿ | 672Gbps/6.72Tbps | 672Gbps/6.72Tbps | 672Gbps/6.72Tbps | 672Gbps/6.72Tbps |
| °üת·¢ÂÊ | 126Mpps | 126Mpps | 126Mpps | 126Mpps |
| ϵͳ¹æ¸ñ | RG-SF2920-8GT2MG2XS-P | RG-SF2920-8GT2XMG2XS-P | RG-SF2920-16GT2SFP-P | RG-SF2920-16GT2MG2XS-P |
| ½»Á÷ÈÝÁ¿ | 672Gbps/6.72Tbps | 672Gbps/6.72Tbps | 672Gbps/6.72Tbps | 672Gbps/6.72Tbps |
| °üת·¢ÂÊ | 126Mpps | 126Mpps | 126Mpps | 126Mpps |
| ϵͳ¹æ¸ñ | RG-SF2920-16GT2XMG2XS-UP |
| ½»Á÷ÈÝÁ¿ | 672Gbps/6.72Tbps |
| °üת·¢ÂÊ | 126Mpps |
| µçÔ´Ó빦ºÄ | RG-SF2920-8GT4XS | RG-SF2920-8GT2MG2XS | RG-SF2920-16GT2SFP | RG-SF2920-16GT2MG2XS |
| µçÔ´ | ¹Ì»¯µ¥½»Á÷µçÔ´ | ¹Ì»¯µ¥½»Á÷µçÔ´ | ¹Ì»¯µ¥½»Á÷µçÔ´ | ¹Ì»¯µ¥½»Á÷µçÔ´ |
| µçÔ´ÊäÈë | ½»Á÷£¨AC£©ÊäÈ룺
¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺֧³Ö |
½»Á÷£¨AC£©ÊäÈ룺
¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺֧³Ö |
½»Á÷£¨AC£©ÊäÈ룺
¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺֧³Ö |
½»Á÷£¨AC£©ÊäÈ룺
¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺֧³Ö |
| Õû»ú¹¦ºÄ | <25W | <25W | <25W | <25W |
| PoE | ²»Ö§³Ö | ²»Ö§³Ö | ²»Ö§³Ö | ²»Ö§³Ö |
| µçÔ´Ó빦ºÄ | RG-SF2920-8GT2MG2XS-P | RG-SF2920-8GT2XMG2XS-P | RG-SF2920-16GT2SFP-P | RG-SF2920-16GT2MG2XS-P |
| µçÔ´ | ¹Ì»¯µ¥½»Á÷µçÔ´ | ¹Ì»¯µ¥½»Á÷µçÔ´ | ¹Ì»¯µ¥½»Á÷µçÔ´ | ¹Ì»¯µ¥½»Á÷µçÔ´ |
| µçÔ´ÊäÈë | ½»Á÷£¨AC£©ÊäÈ룺
¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺֧³Ö |
½»Á÷£¨AC£©ÊäÈ룺
¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺֧³Ö |
½»Á÷£¨AC£©ÊäÈ룺
¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺֧³Ö |
½»Á÷£¨AC£©ÊäÈ룺
¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺֧³Ö |
| Õû»ú¹¦ºÄ | ²»´øPoE¸ºÔØ£º<25W PoEÂúÔØ£º<150W |
²»´øPoE¸ºÔØ£º<25W PoEÂúÔØ£º<150W |
²»´øPoE¸ºÔØ£º<25W PoEÂúÔØ£º<150W |
²»´øPoE¸ºÔØ£º<25W PoEÂúÔØ£º<150W |
| PoE½Ó¿Ú | 1~8ºÅµç¿ÚÖ§³ÖPoE/PoE+¹©µç | 1~2ºÅµç¿ÚÖ§³ÖPoE/PoE+/PoE++¹©µç£¬3~10ºÅµç¿ÚÖ§³ÖPoE/PoE+ | 1~8ºÅµç¿ÚÖ§³ÖPoE/PoE+¹©µç | 1~8ºÅµç¿ÚÖ§³ÖPoE/PoE+¹©µç |
| PoE±ê×¼ | PoE¹©µçÉè¼ÆÖ§³ÖIEEE 802.3af£¨15.4W£©¡¢IEEE 802.3at£¨30W£© | PoE¹©µçÉè¼ÆÖ§³ÖIEEE 802.3af£¨15.4W£©¡¢IEEE 802.3at£¨30W£©¡¢IEEE 802.3bt£¨60W£© | PoE¹©µçÉè¼ÆÖ§³ÖIEEE 802.3af£¨15.4W£©¡¢IEEE 802.3at£¨30W£© | PoE¹©µçÉè¼ÆÖ§³ÖIEEE 802.3af£¨15.4W£©¡¢IEEE 802.3at£¨30W£© |
| PoEÊä³ö¹¦ÂÊ | Õû»ú×î´ó125W | Õû»ú×î´ó125W | Õû»ú×î´ó125W | Õû»ú×î´ó125W |
| PoE¹¦Ð§ | Ö§³Ö×Ô¶¯¡¢½ÚÄܹ©µç¹ÜÀíģʽ Ö§³ÖÈÈÆô¶¯²»ÖÐÖ¹¹©µç Ö§³Ö¶Ë¿ÚÓÅÏȼ¶ Ö§³Ö¶ÔPoE¶Ë¿Ú׼ʱÉÏϵç |
Ö§³Ö×Ô¶¯¡¢½ÚÄܹ©µç¹ÜÀíģʽ Ö§³ÖÈÈÆô¶¯²»ÖÐÖ¹¹©µç Ö§³Ö¶Ë¿ÚÓÅÏȼ¶ Ö§³Ö¶ÔPoE¶Ë¿Ú׼ʱÉÏϵç |
Ö§³Ö×Ô¶¯¡¢½ÚÄܹ©µç¹ÜÀíģʽ Ö§³ÖÈÈÆô¶¯²»ÖÐÖ¹¹©µç Ö§³Ö¶Ë¿ÚÓÅÏȼ¶ Ö§³Ö¶ÔPoE¶Ë¿Ú׼ʱÉÏϵç |
Ö§³Ö×Ô¶¯¡¢½ÚÄܹ©µç¹ÜÀíģʽ Ö§³ÖÈÈÆô¶¯²»ÖÐÖ¹¹©µç Ö§³Ö¶Ë¿ÚÓÅÏȼ¶ Ö§³Ö¶ÔPoE¶Ë¿Ú׼ʱÉÏϵç |
| µçÔ´Ó빦ºÄ | RG-SF2920-16GT2XMG2XS-UP |
| µçÔ´ | ¹Ì»¯µ¥½»Á÷µçÔ´ |
| µçÔ´ÊäÈë | ½»Á÷£¨AC£©ÊäÈ룺
¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺֧³Ö |
| Õû»ú¹¦ºÄ | ²»´øPoE¸ºÔØ£º<25W PoEÂúÔØ£º<295W |
| PoE½Ó¿Ú | 1~2ºÅµç¿ÚÖ§³ÖPoE/PoE+/PoE++¹©µç£¬µ¥¿Ú×î´ó90W£» 3~4ºÅµç¿ÚÖ§³ÖPoE/PoE+/PoE++¹©µç£¬µ¥¿Ú×î´ó60W£» 5~18ºÅµç¿ÚÖ§³ÖPoE/PoE+¹©µç£¬µ¥¿Ú×î´ó30W |
| PoE±ê×¼ | PoE¹©µçÉè¼ÆÖ§³ÖIEEE 802.3af£¨15.4W£©¡¢IEEE 802.3at£¨30W£©¡¢IEEE 802.3bt£¨60W/90W£© |
| PoEÊä³ö¹¦ÂÊ | Õû»ú×î´ó250W |
| PoE¹¦Ð§ | Ö§³Ö×Ô¶¯¡¢½ÚÄܹ©µç¹ÜÀíģʽ Ö§³ÖÈÈÆô¶¯²»ÖÐÖ¹¹©µç Ö§³Ö¶Ë¿ÚÓÅÏȼ¶ Ö§³Ö¶ÔPoE¶Ë¿Ú׼ʱÉÏϵç |
| ³ß´ç | RG-SF2920-8GT4XS | RG-SF2920-8GT2MG2XS | RG-SF2920-16GT2SFP | RG-SF2920-16GT2MG2XS |
| ²úÆ·³ß´ç£¨¿íxÉîx¸ß£© | 210mm x 235mm x 55mm | 210mm x 235mm x 55mm | 210mm x 235mm x 55mm | 210mm x 235mm x 55mm |
| ³ß´ç | RG-SF2920-8GT2MG2XS-P | RG-SF2920-8GT2XMG2XS-P | RG-SF2920-16GT2SFP-P | RG-SF2920-16GT2MG2XS-P |
| ²úÆ·³ß´ç £¨¿íxÉîx¸ß£© |
210mm x 235mm x 55mm | 210mm x 235mm x 55mm | 210mm x 235mm x 55mm | 210mm x 235mm x 55mm |
| ³ß´ç | RG-SF2920-16GT2XMG2XS-UP |
| ²úÆ·³ß´ç £¨¿íxÉîx¸ß£© |
210mm x 250mm x 55mm |
| ÇéÐÎÓë¿É¿¿ÐÔ | RG-SF2920-8GT4XS RG-SF2920-8GT2MG2XS RG-SF2920-16GT2SFP RG-SF2920-16GT2MG2XS |
RG-SF2920-8GT2MG2XS-P RG-SF2920-8GT2XMG2XS-P RG-SF2920-16GT2SFP-P RG-SF2920-16GT2MG2XS-P RG-SF2920-16GT2XMG2XS-UP |
| µçÉÈ | Ö§³ÖÎÞµçÉÈ£¬×ÔȻɢÈÈ | |
| ÎÂ¶È | ÊÂÇéζȣº0¡æ~45¡æ ´æ´¢Î¶ȣº-40¡æ~70¡æ |
|
| ʪ¶È | ÊÂÇéʪ¶È£º5%~95%RH ´æ´¢Êª¶È£º5%~95%RH |
|
| Èí¼þ¹æ¸ñ | RG-SF2920-8GT4XS RG-SF2920-8GT2MG2XS RG-SF2920-16GT2SFP RG-SF2920-16GT2MG2XS |
RG-SF2920-8GT2MG2XS-P RG-SF2920-8GT2XMG2XS-P RG-SF2920-16GT2SFP-P RG-SF2920-16GT2MG2XS-P RG-SF2920-16GT2XMG2XS-UP |
| STP | Ö§³Ö | |
| RSTP | Ö§³Ö | |
| MSTP | Ö§³Ö | |
| RLDP | Ö§³Ö | |
| MACµØÖ·±í | Ö§³Ö¾²Ì¬MACµØÖ· Ö§³ÖMACµØÖ·¹ýÂË |
|
| 802.1Q VLAN | Ö§³Ö4K 802.1Q VLAN Ö§³ÖPort based VLAN Ö§³ÖMAC based VLAN Ö§³ÖPrivate VLAN Ö§³ÖProtocol based VLAN Ö§³ÖGVRP Ö§³ÖVoice VLAN |
|
| QinQ | Ö§³Ö»ù±¾QinQ Ö§³ÖÎÞаQinQ |
|
| ¶þ²ã»·ÍøÊÖÒÕ | Ö§³ÖG.8032¹ú¼Ê±ê×¼»·ÍøÐÒéERPS£¬Çл»Ê±¼ä¡Ü50ms£¬¿ÉÓëÆäËûÖ§³Ö¸ÃÐÒéµÄ²úÆ·ÍêÉÆ¼æÈÝ | |
| ¶Ë¿Ú¾ÛºÏ | Ö§³ÖÁ÷Á¿Æ½ºâ·½·¨ Ö§³ÖLACP¶¯Ì¬¾ÛºÏ Ö§³ÖLACPÓÅÏȼ¶/ÐÉÌ·½·¨ /×î´ó¿É¾ÛºÏ¿ÚÊýÄ¿ÉèÖà |
|
| Mirror | Ö§³ÖͨË×ÓªÒµ¿Ú¡¢¾ÛºÏ¶Ë¿Ú×÷Ϊ¾µÏñµÄÔ´ÒÔ¼°Ä¿µÄ¶Ë¿Ú Ö§³Ö»ùÓÚÁ÷¡¢»ùÓÚVLANµÄ¶Ë¿Ú¾µÏñ Ö§³ÖÒ»¶ÔÒ»¡¢Ò»¶Ô¶à¡¢¶à¶ÔÒ»µÄ¾µÏñ£¬Ö§³ÖRSPAN¡¢ERSPAN |
|
| DHCP | Ö§³ÖDHCP Server Ö§³ÖDHCP Client Ö§³ÖDHCP Snooping Ö§³ÖDHCP Relay |
|
| IP·ÓÉ | Ö§³Ö¾²Ì¬ºÚ¶´Â·ÓÉ¡¢RIP¡¢RIPng¡¢OSPF¡¢OSPFv3ÐÒé | |
| ACL | Ö§³Ö±ê×¼IP ACL£¨»ùÓÚIPµØÖ·µÄÓ²¼þACL£© Ö§³ÖÀ©Õ¹IP ACL£¨»ùÓÚIPµØÖ·¡¢TCP/UDP¶Ë¿ÚºÅµÄÓ²¼þACL£© Ö§³ÖMACÀ©Õ¹ACL£¨»ùÓÚÔ´MACµØÖ·¡¢Ä¿µÄMACµØÖ·ºÍ¿ÉÑ¡µÄÒÔÌ«ÍøÀàÐ͵ÄÓ²¼þACL£© Ö§³Ö»ùÓÚʱ¼äACL Ö§³ÖACL80 Ö§³ÖIPv6 ACL Ö§³ÖÈ«¾ÖACL Ö§³ÖACLÖØ¶¨Ïò |
|
| QoS | Ö§³Ö¶Ë¿ÚÁ÷Á¿Ê¶±ð Ö§³Ö¶Ë¿ÚÁ÷Á¿ÏÞËÙ Ö§³Ö802.1p/DSCP/TOSÁ÷Á¿·ÖÀà ÿ¶Ë¿Ú8¸öÓÅÏȼ¶ÐÐÁÐ Ö§³ÖSP¡¢WRR¡¢DRR¡¢SP+WFQ¡¢ SP+WRR¡¢SP+DRR¡¢RED/WREDÐÐÁе÷Àí |
|
| Çå¾²ÌØÕ÷ | ¹ýÂ˲»·¨µÄMACµØÖ· Ö§³Ö¹ã²¥·ç±©ÒÖÖÆ ¹ÜÀíÔ±·Ö¼¶¹ÜÀíºÍ¿ÚÁî±£»¤ Ö§³ÖRADIUS ºÍ TACACS+ Ö§³ÖSSH ºÍ SSH V2.0 Ö§³ÖBPDU Guard Ö§³ÖCPP¡¢NFPP Ö§³Ö¶Ë¿Ú±£»¤ |
|
| EEE | Ö§³ÖIEEE 802.3az±ê×¼µÄEEE½ÚÄÜÊÖÒÕ£ºµ±EEEʹÄÜʱ£¬´Ó¶ø´ó·ù¶ÈµÄ¼õС¶Ë¿ÚÔڸý׶εŦºÄ£¬µÖ´ïÁ˽ÚÄܵÄÄ¿µÄ | |
| ¹ÜÀíÌØÕ÷ | SNMP¡¢CLI(Telnet/Console)¡¢RMON¡¢SSH¡¢Syslog/Debug¡¢NTP/SNTP¡¢FTP¡¢TFTP¡¢Web¡¢RLDP | |
×°±¸³ß´çÏà½ÏÉÏÒ»´ú¸üСÇÉ£¬ºÏ¹æµÄ¿ª¿×ÂÊ¡¢ÓÅÒìµÄ¿Õ¼ä½á¹¹£¬Ö±½ÇÍäµçÔ´²åÍ·£¬ÓÐÓðü¹ÜÇå¾²£¬Á¢ÒìöèÓã÷¢Éè¼Æ£¬É¢ÈÈÃæ»ýÔö´ó£¬É¢ÈÈЧ¹ûÉÏÉý£¬ÔËÐиüÇå¾²¡£
×°±¸ÅäºÏINC¿ØÖÆÆ÷¿ÉʵÏÖ£¬×°±¸¿ìËÙÉÏÏߣ¬¼´²å¼´Óã¬ÎÞÐèµ÷ÊÔ£¬¾ßÓÐÁ´Â·¹ÊÕ϶¨Î»¹¦Ð§£¬ÅäºÏINC¿É×ÔÖ÷Éó²éÁ´Â·¿µ½¡×´Ì¬ÒÔ¼°¸æ¾¯ÐÅÏ¢£¬ÅÅÕÏЧ̹ÂÊÏßÉÏÉý£¬²¢ÊµÏÖ0ÉèÖÃÌæ»»×°±¸£¬Ïß·ÎÞÐè±ä»»£¬Æ¾Ö¤ÐèÇóÎÞÐ°Ìæ»»²î±ð½»Á÷»ú¡£