97¹ú¼Ê

Àë±ðÔËάÄÚÚ§ È«ÓòЭͬÌáЧ Ø­ 97¹ú¼ÊÍøÂçÔËά°ü¹ÜÂÄÀú·ÖÏí»á
Ô¤Ô¼Ö±²¥
ÎÞ¸Ð×¼Èë ÈËÎïͳ¹Ü Ø­ RG-SAM+5.X ÐÂÒ»´ú¸ßУAIÈÏ֤ƽ̨Ðû²¼
Ô¤Ô¼Ö±²¥
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
²úÆ·
< ·µ»ØÖ÷²Ëµ¥
²úÆ·ÖÐÐÄ
²úÆ·
½â¾ö¼Æ»®
< ·µ»ØÖ÷²Ëµ¥
½â¾ö¼Æ»®ÖÐÐÄ
ÐÐÒµ
ºÏ×÷»ï°é
·µ»ØÖ÷²Ëµ¥
Ñ¡ÔñÇøÓò/ÓïÑÔ
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
RG-S5750V2-28SFP4XS-L
RG-S5750V2-28SFP4XS-L
RG-S5750V2-28SFP4XS-L
RG-S5750V2-28SFP4XS-L
RG-S5750V2-28SFP4XS-L
RG-S5750V2-28SFP4XS-L
RG-S5750V2-28SFP4XS-L
RG-S5750V2-28SFP4XS-L
RG-S5750V2-28SFP4XS-L
RG-S5750V2-28SFP4XS-L
RG-S5750V2-28SFP4XS-L
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
¼ÓÔØÖÐ...0%
ͼƬ

24¿ÚǧÕ×¹âÈý²ãÍø¹ÜÐͽ¹µã»ã¾ÛÒÔÌ«Íø½»Á÷»ú£¨¼Ó8¸öCOMBO¿Ú£© £¬ÍòÕ×ÉÏÐÐ £¬RG-S5750V2-28SFP4XS-L

ÓÃÓÚÖÐСÐÍÍøÂç»ã¾ÛÒÔ¼°½¹µã½»Á÷»ú £¬º¬8¸ö¸´ÓÃǧÕ×µç¿Ú

²úÆ·ÌØÕ÷£º

  • ¶Ë¿ÚÀàÐ͸»ºñ £¬28¸öSFP¹â¿Ú£¨º¬8¸öCOMBO¿Ú£© £¬4¸ö10G¹â¿ÚÓÃÓÚÉÏÁª
  • Ö§³ÖVSUÐéÄ⻯ÊÖÒÕ £¬ÎÞа×éÍøÐÔÄÜÇ¿
  • Èý²ã·ÓÉЭÒé°Ñ¿Ø £¬ÊÊÅä¶àÖØÓªÒµ £¬ÐÅÏ¢´«Êä¸ßЧÓаü¹Ü
  • ÍøÂçÇ徲ʵʱ¼à²â £¬Ö§³ÖCPP¡¢NFPP¡¢RLDP £¬°ü¹ÜÍøÂçÒ»Á¬½áʵÐÔ
  • ÍêÉÆµÄQoSÕ½ÂÔ £¬ÎÞа·ÖÅÉÍøÂç×ÊÔ´ £¬ËÙÂÊÎȹ̲»Óµ¶Â
  • Ö§³ÖSNMP¡¢RMON¡¢Syslog¡¢USBÌØÕ÷¼°CLI¡¢WebÍø¹Ü¡¢TelnetµÈ¶àÖØ¹ÜÀí·½·¨ £¬Ò×ά»¤
Á¬Ã¦×Éѯ
Èý²ãǧÕ×½¹µã&»ã¾Û½»Á÷»ú RG-S5750V2-28SFP4XS-L
¿ÉÓÃÓÚÖÐСÐÍÔ°ÇøÍøÂç»ã¾Û×°±¸ £¬ÓµÓÐ28¸öǧÕ×SFP¶Ë¿Ú£¨º¬8¸öCOMBO¿Ú£© £¬4¸öÍòÕ×ÉÏÐйâ
¿Ú £¬ÎªÔ¶¾àÀëÓªÒµÌṩÎÞÐ°ÍøÂç°²ÅÅ £¬ËÙÂÊÉý¼¶

¿ÉÓÃÓÚÖÐСÆóÒµ½¹µã×°±¸ £¬¾ßÓи߿ɿ¿ÐÔ £¬¸ßЧÐÔ £¬ÈßÓàÐÔ £¬¿É¹ÜÀíÐÔµÈ £¬¸ÄÉÆÍøÂçÐÔÄÜ
Ö§³ÖVSUÐéÄ⻯ÊÖÒÕ £¬ÎÞа×éÍøÐÔÄÜÇ¿
ºÁÃë¼¶¹ÊÕϻָ´
¸ßÀ©Õ¹
¼ò»¯×éÍø
VSUºÍÍâΧװ±¸Í¨¹ý¾ÛºÏÁ´Â·ÅþÁ¬ÈçÓö¹ÊÕÏ £¬¿ÉºÁÃë¼¶Çл»Á´Â· £¬°ü¹ÜÍøÂç²»ÖÐÖ¹
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
Èý²ã·Óɹ¦Ð§°Ñ¿Ø £¬ÊÊÅä¶àÖØÓªÒµ £¬ÐÅÏ¢´«Êä¸ßЧÓаü¹Ü
IPV4¡¢IPV6ЭÒé
¸»ºñµÄ×鲥ЭÒé
¾²Ì¬¡¢¶¯Ì¬Â·ÓÉ
Ó²¼þÖ§³Ö˫ЭÒéÕ»ÐÅÏ¢¸ßËÙ½»Á÷ £¬Öª×ã´ÓÔ°ÇøIPV4µ½IPV6µÄÍøÂç¹ý¶É £¬µØÖ·ÈÝÁ¿ÓëÍøÂçÇå¾²´ó´óÌáÉý
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
¶àÖÖÍøÂçÇå¾²Õ½ÂÔ £¬ÊµÊ±¼à²â £¬°ü¹ÜÍøÂçÒ»Á¬½áʵÐÔ
CPP±£»¤Õ½ÂÔ
NFPP±£»¤Õ½ÂÔ
´ó×Ú¡¢ÔÓÂÒÊý¾ÝÏȾ­ÓÉCPP´¦Öóͷ£ £¬±ÜÃâÖ±½Ó¹¥»÷µ½CPU £¬°ü¹ÜCPU¸ßÔËתϵÄÎȹÌÐÔ £¬ÓÐÓÃÌá¸ß×°±¸µÄÇå¾²ÐÔÄÜ
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
ÍêÉÆµÄQoSÕ½ÂÔ £¬ÊµÏÖÍøÂç×ÊÔ´ÎÞа·ÖÅÉ £¬ËÙÂÊÎȹ̲»Óµ¶Â
¾ß±¸MACÁ÷¡¢IPÁ÷¡¢Ó¦ÓÃÁ÷µÈ¶à²ãÁ÷·ÖÀàºÍÁ÷¿ØÖÆÄÜÁ¦
°ü¹Ü¶àÓªÒµÁ÷Á¿¾«×¼·ÖÅÉ £¬ÊµÏÖÓÃÍø²»Óµ¶Â £¬Ìṩ¸ßÖÊÁ¿ÍøÂç
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
¶àÖØÍøÂç¹ÜÀí·½·¨ ʵÏÖ¼òÆÓÇáËɵÄÍøÂçά»¤
¹ÜÀíÌØÕ÷
¹ÜÀí·½·¨
¶ą̀װ±¸¹ÜÀí
Ö§³ÖRMON¡¢Syslog¡¢USB±¸·ÝÈÕÖ¾ÌØÕ÷ £¬°ü¹ÜÒ»Ñùƽ³£ÓÃÍøµÄÕý³£Õï¶ÏÓëά»¤
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾

ÊÖÒÕ²ÎÊý

Ó²¼þ¹æ¸ñ

ϵͳ¹æ¸ñ

²úÆ·ÐͺŠRG-S5750V2-28GT4XS-L RG-S5750V2-28SFP4XS-L RG-S5750V2-48GT4XS-L
½»Á÷ÈÝÁ¿ 1.28Tbps/12.8Tbps 1.28Tbps/12.8Tbps 1.28Tbps/12.8Tbps
°üת·¢ÂÊ 228Mpps 228Mpps 264Mpps
POE¹©µç±ê×¼ ²»Ö§³Ö
ÎÂ¶È¼à¿Ø ÎÂ¶È¼à¿Ø£ºÖ§³Ö
ζȸ澯£ºÖ§³Ö
¹ýα£»¤£º²»Ö§³Ö
µçÉÈ¼à¿Ø ¹ÊÕϸ澯£ºÖ§³Ö
ÊÖ¶¯µ÷ËÙ£º²»Ö§³Ö
ÖÇÄܵ÷ËÙ£ºÖ§³Ö
µçÔ´¼à¿Ø Ä£¿é¼à¿Ø£º²»Ö§³Ö
¹ÊÕϸ澯£ºÖ§³Ö
ÖÇÄÜÉϵ磺²»Ö§³Ö

½Ó¿ÚÓë²å²Û

²úÆ·ÐͺŠRG-S5750V2-28GT4XS-L RG-S5750V2-28SFP4XS-L RG-S5750V2-48GT4XS-L
¹Ì»¯ÓªÒµ½Ó¿Ú 28¸ö10/100/1000Base-T×Ô˳ӦÒÔÌ«Íø½Ó¿Ú£¨º¬4¸ö100/1000M SFP¹âµç¸´Óýӿڣ©
4¸ö1G/10G SFP+½Ó¿Ú
28¸ö100/1000M SFP½Ó¿Ú£¨º¬8¸ö10/100/1000Base-T¹âµç¸´Óýӿڣ©
4¸ö1G/10G SFP+½Ó¿Ú
48¸ö10/100/1000Base-T×Ô˳ӦÒÔÌ«Íø½Ó¿Ú
4¸ö1G/10G SFP+½Ó¿Ú
¹Ì»¯¹ÜÀí½Ó¿Ú 1¸öRJ45µÄMGMT½Ó¿Ú
1¸öUSB 2.0½Ó¿Ú
1¸öRJ45 Console½Ó¿Ú
1¸öRJ45µÄMGMT½Ó¿Ú
1¸öUSB 2.0½Ó¿Ú
1¸öRJ45 Console½Ó¿Ú
1¸öRJ45µÄMGMT½Ó¿Ú
1¸öUSB 2.0½Ó¿Ú
1¸öRJ45 Console½Ó¿Ú
µçÔ´Ä£¿é²å²Û 2 2 2
µçÔ´Ä£¿éÐͺŠRG-PA70I
RG-PD70I
RG-PA70I
RG-PD70I
RG-PA70I
RG-PD70I
¹Ì»¯µçÉÈÊýÄ¿ 3 3 2

³ß´çÓëÖØÁ¿

²úÆ·ÐͺŠRG-S5750V2-28GT4XS-L RG-S5750V2-28SFP4XS-L RG-S5750V2-48GT4XS-L
²úÆ·³ß´ç
£¨¿í×Éî׸ߣ©
440mm x 280mm x 44mm 440mm x 300mm x 44mm 440mm x 300mm x 44mm
ÖØÁ¿ 3.9kg 4.2kg 4.2kg
»ú¼Ü³ß´ç 1RU 1RU 1RU
×°Ö÷½·¨ ×ÀÃæ/±Ú¹Ò/»ú¼Ü£¨¹ñ£©

µçÔ´Ó빦ºÄ

²úÆ·ÐͺŠRG-S5750V2-28GT4XS-L RG-S5750V2-28SFP4XS-L RG-S5750V2-48GT4XS-L
¶î¶¨ÊäÈëµçѹ RG-PA70I£º100V AC~240V AC £¬50~60Hz
RG-PD70I£º192V DC~288V DC
×î´óÊäÈëµçѹ¹æÄ£ RG-PA70I£º90V AC~264V AC £¬50~60Hz
¶î¶¨ÊäÈëµçÁ÷ 2A
µçÔ´ÈßÓ౸·Ý 1+1
Õû»ú×î´ó¹¦ºÄ 45W£¨²»º¬À©Õ¹¿¨£© 55W£¨²»º¬À©Õ¹¿¨£© 55W£¨²»º¬À©Õ¹¿¨£©

ÇéÐÎÓë¿É¿¿ÐÔ

²úÆ·ÐͺŠRG-S5750V2-28GT4XS-L RG-S5750V2-28SFP4XS-L RG-S5750V2-48GT4XS-L
µçÔ´ÈȲå°Î Ö§³Ö
ÏßÀÂÈȲå°Î Console¿Ú¡¢USB¿Ú¡¢ÓªÒµ½Ó¿ÚÓëµçÔ´½Ó¿ÚÖ§³Ö
ÎÂ¶È ÊÂÇéζȣº0°C~45°C
´æ´¢Î¶ȣº-40°C~70°C º£°Î3000~5000m£ºº£°ÎÿÉý¸ß220m £¬×î¸ßζȹæ¸ñ½µµÍ1¡æ¡£
ʪ¶È ÊÂÇéʪ¶È£º10%RH~90%RH£¨ÎÞÄý¾Û£©
´æ´¢Êª¶È£º5%RH~95%RH£¨ÎÞÄý¾Û£©
ÔëÉù £¼78dBA
É¢ÈÈ ·çÀäÉ¢ÈÈ £¬×ó½øÓÒ³ö

Èí¼þ¹æ¸ñ

²úÆ·ÐͺŠRG-S5750V2-28GT4XS-L RG-S5750V2-28SFP4XS-L RG-S5750V2-48GT4XS-L
VLAN Ö§³Ö4K 802.1Q VLAN
Ö§³ÖPort based VLAN
Ö§³ÖMAC based VLAN
Ö§³ÖProtocol based VLAN
Ö§³ÖPrivate VLAN
Ö§³ÖVoice VLAN
Ö§³ÖIP subnet-based VLAN
Ö§³ÖGVRP
Ö§³ÖÕ½ÂÔVLAN
QinQ Ö§³Ö»ù±¾QinQ
Ö§³ÖÎÞаQinQ
Á´Â·¾ÛºÏ Ö§³ÖLACP(802.3ad)
¶Ë¿Ú¾µÏñ Ö§³ÖÒ»¶ÔÒ»¾µÏñ
Ö§³Ö»ùÓÚÁ÷µÄ¾µÏñ
ÌìÉúÊ÷ Ö§³ÖSTP¡¢RSTP¡¢MSTP
DHCP Ö§³ÖDHCP Server
Ö§³ÖDHCP Client
Ö§³ÖDHCP Snooping
Ö§³ÖDHCP Relay
Ö§³ÖIPv6 DHCP Snooping
Ö§³ÖIPv6 DHCP Client
Ö§³ÖIPv6 DHCP Relay
IPv6»ù´¡Ð­Òé IPv6±àÖ·¡¢ÁÚÈË·¢Ã÷ЭÒ飨ND£©¡¢ND-Snooping¡¢ICMPv6¡¢ÎÞ״̬×Ô¶¯ÉèÖá¢Path MTU Discovery
IP·ÓÉ Ö§³Ö¾²Ì¬Â·ÓÉ
Ö§³ÖRIP £¬RIPng
Ö§³ÖOSPFv2 £¬OSPFv3 £¬IS-ISv4 £¬IS-ISv6
Ö§³ÖBGP4 £¬BGP4+
Ö§³ÖµÈ¼Û·ÓÉ
Ö§³Ö»ùÓÚ°üµÄ¸ºÔØÆ½ºâºÍ»ùÓÚÁ÷µÄ¸ºÔØÆ½ºâ
×é²¥ Ö§³ÖIGMP v1 £¬v2 £¬v3 £¬IGMP ´úÀí
Ö§³ÖIGMP v1 £¬v2ºÍv3 Snooping
Ö§³ÖIGMP ¹ýÂË £¬ IGMP¿ìËÙÍÑÀë
Ö§³ÖPIM-DM £¬PIM-SM £¬PIM-SSM
Ö§³ÖMLD Snooping £¬MLD
Ö§³ÖPIM for IPv6
Ö§³ÖMSDP
ACL Ö§³ÖÎÞа¶àÑùµÄÓ²¼þACL£º
Ö§³Ö±ê×¼IP ACL£¨»ùÓÚIPµØÖ·µÄÓ²¼þACL£©
Ö§³ÖÀ©Õ¹IP ACL£¨»ùÓÚIPµØÖ·¡¢TCP/UDP¶Ë¿ÚºÅµÄÓ²¼þACL£©
Ö§³ÖMACÀ©Õ¹ACL£¨»ùÓÚÔ´MACµØÖ·¡¢Ä¿µÄMACµØÖ·ºÍ¿ÉÑ¡µÄÒÔÌ«ÍøÀàÐ͵ÄÓ²¼þACL£©
Ö§³Ö»ùÓÚʱ¼äACL
Ö§³Öר¼Ò¼¶ACL£¨¿Éͬʱ»ùÓÚVLANºÅ¡¢ÒÔÌ«ÍøÀàÐÍ¡¢MACµØÖ·¡¢IPµØÖ·¡¢TCP/UDP¶Ë¿ÚºÅ¡¢Ð­ÒéÀàÐÍ¡¢Ê±¼äµÈÎÞа×éºÏµÄÓ²¼þACL£©
Ö§³ÖACL80
Ö§³ÖIPv6 ACL
QoS Ö§³Ö¶Ë¿ÚÁ÷Á¿Ê¶±ð
Ö§³Ö¶Ë¿ÚÁ÷Á¿ÏÞËÙ
Ö§³Ö802.1p/DSCP/ToSÁ÷Á¿·ÖÀà
ÿ¶Ë¿Ú8¸öÓÅÏȼ¶ÐÐÁÐ
Ö§³ÖSP¡¢WRR¡¢DRR¡¢SP+WFQ¡¢ SP+WRR¡¢SP+DRR¡¢RED/WREDÐÐÁе÷Àí
Çå¾²ÌØÕ÷ Ö§³ÖIP¡¢MAC¡¢¶Ë¿ÚÈýÔªËØ°ó¶¨
Ö§³ÖIPv6¡¢MAC¡¢¶Ë¿ÚÈýÔªËØ°ó¶¨
¹ýÂ˲»·¨µÄMACµØÖ·
Ö§³ÖARP-Check
Ö§³ÖDAI
Ö§³ÖARP±¨ÎÄÏÞËÙ
Ö§³Ö·ÀÍø¹ØARPÓÕÆ­
Ö§³Ö¹ã²¥·ç±©ÒÖÖÆ
¹ÜÀíÔ±·Ö¼¶¹ÜÀíºÍ¿ÚÁî±£»¤
Ö§³ÖRADIUS ºÍ TACACS+
×°±¸Éϰ¶¹ÜÀíµÄAAAÇå¾²ÈÏÖ¤£¨IPv4/IPv6£©
Ö§³ÖSSH
Ö§³ÖBPDU Guard
Ö§³ÖIP Source Guard
Ö§³ÖCPP¡¢NFPP
Ö§³Ö¶Ë¿Ú±£»¤
¹ÜÀíÌØÕ÷ SNMP¡¢CLI(Telnet/Console)¡¢RMON(1,2,3,9)¡¢SSH¡¢Syslog¡¢NTP/SNTP¡¢SNMP over IPv6¡¢IPv6 MIB support for SNMP ¡¢SSHv6¡¢Telnet v6¡¢FTP/TFTP v6¡¢DNS v6¡¢NTP for v6¡¢Traceroute v6¡¢MACCŵ¿Í¹«ÓÐÔÆÆ½Ì¨¹ÜÀí
¸ß¿É¿¿ÐÔ Ö§³ÖVSU£¨ÐéÄ⻯ÊÖÒÕ £¬½«¶ą̀װ±¸ÐéÄâ³É1̨£©¡¢Ö§³ÖGR for RIP/OSPF/BGPµÈ·ÓÉЭÒé¡¢Ö§³ÖBFD¼ì²â¡¢Ö§³ÖERPS£¨G.8032£©¡¢Ö§³ÖREUP¡¢Ö§³ÖRLDP¡¢Ö§³ÖµçÔ´1+1ÈßÓ౸·Ý¡¢µçÔ´Ä£¿éÖ§³ÖÈȲå°Î¹¦Ð§
EEE Ö§³ÖIEEE 802.3az±ê×¼µÄEEE£¨Energy Efficient Ethernet £¬½ÚÄÜÒÔÌ«Íø£©ÊÖÒÕ

Õö¿ªÏêϸ²ÎÊý

Ó¦ÓôîÅä

ÍòÕ×Á´Â·
ǧÕ×Á´Â·
ÍÆ¼öÓÃÓÚÖÐСÐÍÆóÒµÔ°ÇøÍø £¬½ÌÓýÐ£Ô°Íø/³ÇÓòÍø £¬¿í´øÐ¡ÇøÍøÂçµÈ»ã¾Û×°±¸ £¬ÊµÏÖÍòÕ×»ã¾Ûµ½½¹µãµÄ¸ßÐÔÄÜ´ø¿íÁ´Â· £¬Öª×ã½ÓÈëÓû§ÐÅÏ¢Á¿ÈÕÒæÔöÌíµÄÐèÒª
RG-S5750V2-L»ã¾Û½»Á÷»ú
RG-S2910-L½ÓÈë½»Á÷»ú
ÍÆ¼öÓÃÓÚÖÐСÆóÒµÔ°ÇøÍø½¹µã×°±¸ £¬Í¨¹ý1+1µçÔ´ÈßÓà £¬ÌáÉýÓ²¼þ¿É¿¿ÐÔ £¬Ö§³ÖVSUÐéÄ⻯ÊÖÒÕ £¬´ó·ùÌáÉýÍøÂçϵͳµÄ¿É¿¿ÐԺ͸ßЧÐÔ
ÄÚ²¿·þÎñÆ÷
RG-S5750V2-L»ã¾Û½»Á÷»ú
RG-S2910-L½ÓÈë½»Á÷»ú
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾

×ÊÔ´ÖÐÐÄ

ÓªÏú×ÊÁÏ
Ó¦Óð¸Àý
ÊÖÒÕ²©ÎÄ
ÊÛºóÎĵµ

³£¼ûÎÊÌâ

ÎÒÒªÌáÎÊ
ËùÓÐ
µçÔ´(6)
É¢ÈÈ(4)
¶Ë¿Ú(4)
ÊÊÓó¡¾°(1)
·Óɹ¦Ð§(4)
»·Â·¼ì²â(1)
97¹ú¼Ê 2022Äê07ÔÂ25ÈÕ
RG-S5750V2-28GT4XS-LÊÇ·ñÓзÓɹ¦Ð§£¿
ÓÐÓÃ 32 ÎÞÓÃ 6

×°±¸ÊôÓÚÈý²ã½¹µã»ã¾Û½»Á÷»ú £¬¾ßÓÐÈý²ã·ÓÉЭÒéÌØÕ÷ £¬Ö§³ÖIPv4/IPv6˫ЭÒéÕ»¶à²ã½»Á÷£»Ö§³ÖÌìÉúÊ÷ЭÒé802.1D¡¢802.1w¡¢802.1s £¬°ü¹Ü¿ìËÙÊÕÁ²£»²¢Ö§³ÖIGMP Snooping¡¢IGMPµÈ¸»ºñ×鲥ЭÒé £¬ÒÔ¼°¾²Ì¬Â·ÓÉÓëRIP¡¢BGP4µÈ¶¯Ì¬Â·ÓÉ £¬Ìá¸ßÍøÂçÐÔÄÜ¡£

97¹ú¼Ê 2022Äê07ÔÂ25ÈÕ
RG-S5750V2-28SFP4XS-LÓÐÍòÕ×¹â¿ÚÂð£¿
ÓÐÓÃ 31 ÎÞÓÃ 5

ÓеÄ £¬×°±¸ÓµÓÐ28¸öSFP¹â¿Ú £¬8¸ö¸´ÓõÄ10/100/1000M×Ô˳Ӧµç¿Ú £¬4¸ö1G/10G SFP+¹â¿Ú £¬¶Ë¿ÚÊýÄ¿ÌáÉý £¬ÌṩÎÞÐ°ÍøÂç°²ÅÅ¡£

Õö¿ªËùÓÐ
ÈôÊÇÄúÐèÒª¸ü¶à²úÆ·ÊÖÒÕ×Éѯ
ÏêϸÐÔÄÜÄÜ·ñÖª×ãÄúµÄÓªÒµ·åÖµ£¿ÔõÑùÍýÏë°²ÅÅÓëÉèÖã¿
Á¬Ã¦×Éѯ
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾

·µ»Ø¶¥²¿

ÊÕÆð
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾ ÎĵµAIÖúÊÖ
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾ ÎĵµÆÀ¼Û
¸Ã×ÊÁÏÊÇ·ñ½â¾öÁËÄúµÄÎÊÌ⣿
Äú¶ÔÄ¿½ñÒ³ÃæµÄÖª×ã¶ÈÔõÑù£¿
²»Õ¦µÎ
ºÜÊǺÃ
ÄúÖª×ãµÄÔµ¹ÊÔ­ÓÉÊÇ£¨¶àÑ¡£©£¿
Äú²»Öª×ãµÄÔµ¹ÊÔ­ÓÉÊÇ£¨¶àÑ¡£©£¿
ÄúÊÇ·ñÉÐÓÐÆäËûÎÊÌâ»ò½¨Ò飿
ΪÁË¿ìËÙ½â¾ö²¢»Ø¸´ÄúµÄÎÊÌâ £¬Äú¿ÉÒÔÁôÏÂÁªÏµ·½·¨
ÓÊÏä
ÊÖ»úºÅ
ллÄúµÄ·´À¡£¡
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
ÇëÑ¡Ôñ·þÎñÏîÄ¿
¹Ø±Õ×Éѯҳ
ÊÛǰ×Éѯ ÊÛǰ×Éѯ
ÊÛǰ×Éѯ
ÊÛºó·þÎñ ÊÛºó·þÎñ
ÊÛºó·þÎñ
Òâ¼û·´Ïì Òâ¼û·´Ïì
Òâ¼û·´Ïì
¸ü¶àÁªÏµ·½·¨
ÍøÕ¾µØÍ¼