ÖÐÎÄ
| ÐͺŠ| RG-S5315-24MG6XS-UP-E |
| ½Ó¿Ú¹æ¸ñ | |
| Ä£¿é²å²Û | 2¸öµçÔ´Ä£¿é²å²Û |
| ¹Ì»¯ÓªÒµ½Ó¿Ú | 24¸ö100/1000/2500Base-T×Ô˳ӦÒÔÌ«Íø½Ó¿Ú£¬6¸ö1/2.5/10GE SFP+½Ó¿Ú |
| ¹Ì»¯¹ÜÀí½Ó¿Ú | 1¸öRJ45µÄConsole½Ó¿Ú |
| USB½Ó¿Ú | 1¸öUSB½Ó¿Ú |
| µçÔ´Ä£¿é | RG-PA1000I-P-F RG-PD600I-P-F RG-PA600I-P-F |
| USBÈȲå°Î | USB½Ó¿ÚÖ§³ÖÈȲå°Î |
| ÏßÀÂÈȲå°Î | ËùÓнӿÚÖ§³ÖÈȲå°ÎÏßÀ |
| ϵͳ¹æ¸ñ | |
| ½»Á÷ÈÝÁ¿ | 1.36Tbps/13.6Tbps |
| °üת·¢ÂÊ | 225Mpps/770Mpps |
| CPU | MACÄÚÖÃË«ºË´¦Öóͷ£Æ÷£¬µ¥ºËÖ÷Ƶ1GHz |
| Bootrom | 16MB |
| Flash Memory | 256MB |
| ÄÚ´æ | 1GB |
| ³ß´çÓëÖØÁ¿ | |
| ²úÆ·³ß´ç£¨¿í¡ÁÉî¡Á¸ß£© | 442mm¡Á420mm¡Á43.6mm |
| »ú¼Ü³ß´ç | 1U |
| ²úÆ·ÖØÁ¿ | 4.1kg |
| µçÔ´Ó빦ºÄ | |
| µçÔ´ | Ä£¿é»¯Ë«µçÔ´ |
| µçÔ´ÈßÓà | ÔÚË«802.3at»òË«802.3af¹©µçÏ£¬Ö§³Ö¹©µçÈȱ¸ÈßÓà |
| µçÔ´ÈȲå°Î | Ö§³Ö |
| µçÔ´ÊäÈë | RG-PA600I-P-F½»Á÷£¨AC£©ÊäÈ룺 ¡ñ ¶î¶¨ÊäÈëµçѹ£º100V~240V AC£¬50Hz~60Hz ¡ñ ×î´óÊäÈëµçѹ£º90V~264V AC£¬47Hz~63Hz ¡ñ ×î´óÊäÈëµçÁ÷£º8A RG-PA600I-P-F¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺 ¡ñ ¶î¶¨ÊäÈëµçѹ£º240V DC ¡ñ ×î´óÊäÈëµçѹ£º192V~288V DC ¡ñ ×î´óÊäÈëµçÁ÷£º4A RG-PD600I-P-FÖ±Á÷£¨DC£©ÊäÈ룺 ¡ñ ¶î¶¨ÊäÈëµçѹ£º-48V~-60V DC ¡ñ ×î´óÊäÈëµçѹ£º-38V~-75V DC ¡ñ ×î´óÊäÈëµçÁ÷£º20A RG-PA1000I-P-F½»Á÷£¨AC£©ÊäÈë1£º ¡ñ ¶î¶¨ÊäÈëµçѹ£º100V~130V AC£¬50Hz~60Hz ¡ñ ×î´óÊäÈëµçѹ£º90V~143V AC£¬47Hz~63Hz ¡ñ ×î´óÊäÈëµçÁ÷£º12A RG-PA1000I-P-F½»Á÷£¨AC£©ÊäÈë2£º ¡ñ ¶î¶¨ÊäÈëµçѹ£º200V~240V AC£¬50Hz~60Hz ¡ñ ×î´óÊäÈëµçѹ£º180V~264V AC£¬47Hz~63Hz ¡ñ ×î´óÊäÈëµçÁ÷£º8A RG-PA1000I-P-FÖ§³Ö¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺 ¡ñ ¶î¶¨ÊäÈëµçѹ£º240V DC ¡ñ ×î´óÊäÈëµçѹ£º192V~288V DC ¡ñ ×î´óÊäÈëµçÁ÷£º8A |
| µçÔ´×î´óÊä³ö¹¦ÂÊ | RG-PA1000I£º ¡ñ 100V~130V AC£º930W£» ¡ñ 200V~240V AC£º1000W£» ¡ñ 240V DC£º1000W£» RG-PA600I£º ¡ñ 100V~240V AC£º600W£» ¡ñ 240V DC£º600W£» RG-PD600I£º ¡ñ -48V~-60V DC£º600W£» ˵Ã÷£º ¡ñ RG-PA600IµçÔ´Ö§³Ö¸ßѹֱÁ÷Ë«ÏòÊäÈ룬²»±ØÇø·ÖÖ±Á÷ÊäÈëµÄÕý¸º¼«¡£ ¡ñ »ú·¿Ê¹ÓøßѹֱÁ÷ÊäÈëʱ£¬Ó¦Å䱸֧³Ö¸ßѹֱÁ÷ÊäÈëµÄPDU¡£ ¡ñ Åäµç·½Ã潨ÒéÅ䱸ֱÁ÷¿Õ¿ª£ºÉϵçʱ£¬Ó¦ÏȽӺõçÔ´ÏßÔÙ·¿ªÖ±Á÷¿Õ¿ª£»Ïµçʱ£¬Ó¦ÏȶϿª¿Õ¿ªÔٰεçÔ´Ïß¡£ |
| Õû»ú¹¦ºÄ | ¡Ü75W£¨²»´øPoE¸ºÔØ£© <1675W£¨PoEÂúÔØ£© ×¢ÖØ£ºµçÔ´ÈßÓàºÍÂúÔØ×´Ì¬µÄ¹©µç˵Ã÷Ïê¼ûÓ²¼þÊÖ²á |
| PoE½Ó¿Ú | ËùÓÐRJ45¿Ú¾ùÖ§³ÖPoE/PoE+/PoE++ £¨IEEE802.3af/at/bt£©¹©µç |
| PoE¹¦Ð§ | Ö§³Ö×Ô¶¯¡¢½ÚÄܵĹ©µç¹ÜÀíģʽ Ö§³ÖÈÈÆô¶¯²»ÖÐÖ¹¹©µç Ö§³Ö»ùÓÚʱ¼äÕ½ÂÔ¶ÔPoE¶Ë¿Ú׼ʱÉÏϵç Ö§³Ö¶Ë¿ÚÓÅÏȼ¶ |
| PoE¹©µçÏß¶Ô | 4Ïß¶Ô£¨1-2,3-6,4-5,7-8Ïß¶Ô£© |
| PoEÊä³ö¹¦ÂÊ | RG-PA600I-P-F£º470W£¨Ë«µçÔ´940W£© RG-PD600I-P-F£º470W£¨Ë«µçÔ´940W£© RG-PA1000I-P-F£º800W£¨Ë«µçÔ´1600W£© |
| ÇéÐÎÓë¿É¿¿ÐÔ | |
| ÎÂ¶È | ÊÂÇéζÈ0¡æ~45¡æ ´æ´¢Î¶È-40¡æ~70¡æ |
| ʪ¶È | ÊÂÇéʪ¶È10%RH~90%RH ´æ´¢Êª¶È5%RH~95%RH |
| º£°Î | ÊÂÇ麣°Î£º0~5000Ã× ´æ´¢º£°Î£º0~5000Ã× |
| ƽ¾ùÎÞ¹ÊÕÏʱ¼ä£¨MTBF£© | >200000Сʱ |
| µçÉÈ | ¹Ì»¯2µçÉÈ |
| É¢ÈÈ | ×ó²àǰ²à½ø·ç£¬ºó²à³ö·ç |
| ÔëÉù | ³£ÎÂÉùѹ£º 31.9dB£¨Ë«AC 600W PoE 30%¸ºÔØ£© 32.3dB£¨Ë«AC 1000W PoE 30%¸ºÔØ£© |
| µçÔ´¼à¿Ø | »ñÈ¡µçÔ´ÐͺţºÖ§³Ö »ñÈ¡ÔÚλ״̬£ºÖ§³Ö ¹ÊÕϸ澯£ºÖ§³Ö |
| µçÉÈ¼à¿Ø | Ö§³ÖµçÉÈ×Ô¶¯µ÷ËÙ Ö§³ÖµçÉȹÊÕϸ澯 |
| ÎÂ¶È¼à¿Ø | ÎÂ¶È¼à¿Ø£ºÖ§³Ö ζȸ澯£ºÖ§³Ö ¹ýα£»¤£ºÖ§³Ö |
| ¾²µç¿¹ÈÅ | ¿ÕÆø·Åµç£º8KV ½Ó´¥·Åµç£º6KV |
| ·ÀÀ× | ÓªÒµ½Ó¿Ú£º10KV µçÔ´½Ó¿Ú£º¹²Ä£6KV£¬²îÄ£6KV |
| ÀËÓ¿ | ÓªÒµ½Ó¿Ú£º10kV µçÔ´½Ó¿Ú£º6kV |
| ÈÏÖ¤Óë¹æÔò | |
| Çå¾²¹æÔò | GB 4943.1 |
| EMC¹æÔò | GB/T 9254.1 |
| Rohs | ÇкÏRohs 6 |
| ÐͺŠ| RG-S5315-24MG6XS-UP-E |
| 802.1Q VLAN | Ö§³Ö4K 802.1Q VLAN Ö§³ÖPort based VLAN Ö§³ÖMAC based VLAN Ö§³ÖPrivate VLAN Ö§³ÖVoice VLAN Ö§³ÖGVRP |
| QinQ | Ö§³Ö»ù±¾QinQ Ö§³ÖÎÞаQinQ |
| ACL | Ö§³Ö±ê×¼IP ACL£¨»ùÓÚIPµØÖ·µÄÓ²¼þACL£© Ö§³ÖÀ©Õ¹IP ACL£¨»ùÓÚIPµØÖ·¡¢TCP/UDP¶Ë¿ÚºÅµÄÓ²¼þACL£© Ö§³ÖMACÀ©Õ¹ACL£¨»ùÓÚÔ´MACµØÖ·¡¢Ä¿µÄMACµØÖ·ºÍ¿ÉÑ¡µÄÒÔÌ«ÍøÀàÐ͵ÄÓ²¼þACL£© Ö§³Ö»ùÓÚʱ¼äACL Ö§³Öר¼Ò¼¶ACL £¨¿Éͬʱ»ùÓÚVLANºÅ¡¢ÒÔÌ«ÍøÀàÐÍ¡¢MACµØÖ·¡¢IPµØÖ·¡¢TCP/UDP¶Ë¿ÚºÅ¡¢ÐÒéÀàÐÍ¡¢Ê±¼äµÈÎÞа×éºÏµÄÓ²¼þACL£© Ö§³ÖACL80 Ö§³ÖIPv6 ACL Ö§³ÖÈ«¾ÖACL Ö§³ÖACLÖØ¶¨Ïò |
| QoS | Ö§³Ö¶Ë¿ÚÁ÷Á¿Ê¶±ð Ö§³Ö¶Ë¿ÚÁ÷Á¿ÏÞËÙ Ö§³Ö802.1p/DSCP/TOSÁ÷Á¿·ÖÀà ÿ¶Ë¿Ú8¸öÓÅÏȼ¶ÐÐÁÐ Ö§³ÖSP¡¢WRR¡¢SP+WRRÐÐÁе÷Àí |
| Mirror | Ö§³ÖÒ»¶ÔÒ»¡¢¶à¶ÔÒ»¡¢Ò»¶Ô¶àµÄ¾µÏñ Ö§³ÖSPANÍâµØ¾µÏñºÍRSPANÔ¶³Ì¾µÏñ Ö§³Ö»ùÓÚÁ÷µÄÍâµØ¡¢Ô¶³Ì¾µÏñ |
| DHCP | Ö§³ÖDHCP Server Ö§³ÖDHCP Client Ö§³ÖDHCP Snooping Ö§³ÖDHCP Relay Ö§³ÖIPv6 DHCP Snooping Ö§³ÖIPv6 DHCP Client Ö§³ÖIPv6 DHCP Relay |
| Çå¾²ÌØÕ÷ | Ö§³ÖIP¡¢MAC¡¢¶Ë¿ÚÈýÔªËØ°ó¶¨ Ö§³ÖIPv6¡¢MAC¡¢¶Ë¿ÚÈýÔªËØ°ó¶¨ ¹ýÂ˲»·¨µÄMACµØÖ· Ö§³Ö»ùÓڶ˿ںÍMACµÄ802.1x Ö§³ÖMAB Ö§³ÖPortal ºÍPortal 2.0ÈÏÖ¤ Ö§³ÖARP-Check Ö§³ÖDAI Ö§³ÖARP±¨ÎÄÏÞËÙ Ö§³Ö·ÀÍø¹ØARPÓÕÆ Ö§³Ö¹ã²¥·ç±©ÒÖÖÆ ¹ÜÀíÔ±·Ö¼¶¹ÜÀíºÍ¿ÚÁî±£»¤ Ö§³ÖRADIUS ºÍ TACACS+ ×°±¸Éϰ¶¹ÜÀíµÄAAAÇå¾²ÈÏÖ¤£¨IPv4/IPv6£© Ö§³ÖSSH ºÍ SSH V2.0 Ö§³ÖBPDU Guard Ö§³ÖIP SOURCE Guard Ö§³ÖCPP¡¢NFPP Ö§³Ö¶Ë¿Ú±£»¤ |
| »·ÍøÐÒé | Ö§³ÖG.8032¹ú¼Ê±ê×¼»·ÍøÐÒéERPS£¬¿ÉÓëÆäËûÖ§³Ö¸ÃÐÒéµÄ²úÆ·¼æÈÝ |
| PoE | ¹©µçÉè¼ÆÖ§³ÖIEEE 802.3af¡¢802.3atºÍ802.3btµÄ¹©µç±ê×¼ Ö§³Ö×Ô¶¯¡¢½ÚÄܵĹ©µç¹ÜÀíģʽ Ö§³ÖÈÈÆô¶¯²»ÖÐÖ¹¹©µç Ö§³Ö»ùÓÚʱ¼äÕ½ÂÔ¶ÔPoE¶Ë¿Ú׼ʱÉÏϵç Ö§³Ö¶Ë¿ÚÓÅÏȼ¶ |
| IP·ÓÉ | IPv4/IPv6 ¾²Ì¬Â·ÓÉ RIP¡¢RIPng¡¢OSPFv2¡¢OSPFv3 Routing Policy |
| IPv6»ù´¡ÐÒé | IPv6±àÖ·¡¢ÁÚÈË·¢Ã÷ÐÒ飨ND£©¡¢ICMPv6¡¢IPv6 Ping¡¢IPv6 TracertµÈ |
| SAVI | Ö§³Ö·ÀNS/NA/RS/RA±¨ÎÄÓÕÆ¹¦Ð§ Ö§³Ö·À˽ÉèIPv6µØÖ· Ö§³Ö»º´æ²»·¨ÖÕ¶ËÐÅÏ¢ |
| VSUÌØÕ÷ | Ö§³ÖVSUÐéÄ⻯ÊÖÒÕ Ö§³ÖÍâµØ¶ÑµþºÍÔ¶³Ì¶Ñµþ Ö§³Ö¶ÑµþÄÚ¿ç»úÏäµÄÁ´Â·À¦°ó Ö§³Öͨ¹ý±ê×¼ÓªÒµ¿ÚʵÏÖÐéÄ⻯ |
| ¿É¿¿ÐÔ | µçÔ´Ö§³Ö1+1ÈßÓ౸·Ý Ö§³ÖBFD Ö§³Ö»ùÓÚIPv6µÄÍø¹ØÈȱ¸ÐÒé(VRRPv3) |
| ÁãÉèÖà | Ö§³ÖCWMP(TR069)ÐÒé±ê×¼ÐÒé |
| ¹ÜÀíÌØÕ÷ | SNMPv1/v2c/v3¡¢CLI(Telnet/Console)¡¢RMON(1£¬2£¬3£¬9)¡¢Web¡¢SSH¡¢Syslog/Debug¡¢NTP/SNTP¡¢FTP¡¢TFTP¡¢sFLOW |