97¹ú¼Ê

Àë±ðÔËάÄÚÚ§ È«ÓòЭͬÌáЧ Ø­ 97¹ú¼ÊÍøÂçÔËά°ü¹ÜÂÄÀú·ÖÏí»á
Ô¤Ô¼Ö±²¥
ÎÞ¸Ð×¼Èë ÈËÎïͳ¹Ü Ø­ RG-SAM+5.X ÐÂÒ»´ú¸ßУAIÈÏ֤ƽ̨Ðû²¼
Ô¤Ô¼Ö±²¥
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
²úÆ·
< ·µ»ØÖ÷²Ëµ¥
²úÆ·ÖÐÐÄ
²úÆ·
½â¾ö¼Æ»®
< ·µ»ØÖ÷²Ëµ¥
½â¾ö¼Æ»®ÖÐÐÄ
ÐÐÒµ
ºÏ×÷»ï°é
·µ»ØÖ÷²Ëµ¥
Ñ¡ÔñÇøÓò/ÓïÑÔ
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
RG-N18010-E
RG-N18010-E
RG-N18010-E
RG-N18010-E
RG-N18010-E
RG-N18010-E
RG-N18010-E
RG-N18010-E
RG-N18010-E
RG-N18010-E
RG-N18010-E
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
¼ÓÔØÖÐ...0%
ͼƬ

¸ßÃܶȴ󻺴æÔƼܹ¹ÍøÂç½¹µã½»Á÷»ú£¬10U¿òʽ£¬RG-N18010-E

½ÓÄÉÏȽøµÄCLOSÕý½»¼Ü¹¹ºÍRGOS²Ù×÷ϵͳ£¬¸ßÐÔÄÜ£¬Ò×À©Õ¹£¬ÍƼö°²ÅÅÔÚÊý¾ÝÖÐÐÄ¡¢³ÇÓòÍø¡¢Ô°ÇøÍø»òÊý¾ÝÖÐÐÄÓëÔ°ÇøÍøÈںϵij¡¾°£»´îÅä¸ßÃܶȲʹâ°å¿¨¼°³¬¾ÛºÏ²Ê¹âÄ£¿é£¬Ó¦ÓÃÓÚ¼«¼òÒÔÌ«²Ê¹âÍøÂç½â¾ö¼Æ»®4.0

²úÆ·ÌØÕ÷£º

  • Ó¦ÓÃÓÚ¼«¼òÒÔÌ«²Ê¹âÍøÂç½â¾ö¼Æ»®4.0£¬Ò»Ì¨×°±¸³ÐÔØÇ§¼ä·¿
  • Õý½»CLOS¼Ü¹¹£¬ÎÞÛÕ±Õת·¢£¬¸ßËÙ´«Êä²»¶ª°ü
  • ȫеÄÈ«½âñî×é¼þ»¯²Ù×÷ϵͳRGOS£¬¸÷×é¼þÏ໥×ÔÁ¦£¬ÓªÒµÒ»Á¬²»ÖÐÖ¹
  • Ó²¼þ¼¶¶àÖØ±£»¤£¬µçÐż¶¸ß¿É¿¿£¬¼á³Ö×°±¸Ò»Á¬ÔËÐв»µôÏß
  • Á¢ÒìµÄµçÉÈ´®ÁªºÍYÐÍ·çµÀÉè¼Æ£¬É¢Èȸü¸ßЧ£¬ÏµÍ³¿É¿¿ÐÔ¸ü¸ß
  • RG-UNCÍ³Ò»ÍøÂçÖÐÐÄ£¬¼«¼ò»¯Í³Ò»¹ÜÀí£¬×Ô¶¯»¯ÇáËÉÔËά
Á¬Ã¦×Éѯ
Èí¼þЭÒé
¸ß¿É¿¿ÐÔ
GR for OSPF/IS-IS/BGP
BFD for VRRP/OSPF/BGP4/ISIS/ISISv6/¾²Ì¬Â·ÓɵÈ
VSU (Virtual Switching Unit,ÐéÄâ½»Á÷µ¥Î»)
STP¡¢RSTP¡¢MSTP
LLDP
Çå¾²ÌØÕ÷
NFPP£¨»ù´¡Çå¾²±£»¤Õ½ÂÔ£©
CPP£¨CPU±£»¤£©
DAI£¬¶Ë¿ÚÇå¾²£¬IP Source Guard
802.1x
PortalÈÏÖ¤¡¢RADIUS¡¢TACACS+Óû§µÇ¼ÈÏÖ¤
uRPF
µÇ¼ÈÏÖ¤¡¢¿ÚÁîÇå¾²
SSHv2
IPv6 SAVI
Ó¦ÓÃЭÒé
Jumbo Frame
802.1Q
Super VLAN
GVRP
QinQ¡¢ÎÞаQinQ
ERPS£¨G.8032£©
MPLS L3VPN¡¢MPLS 6VPE¡¢MPLS IPv6
IPv4/IPv6
IGMP v1,v2,v3¡¢IGMP Snooping¡¢IGMP Proxy
¹ÜÀíÌØÕ÷
Console/AUX Modem/Telnet/SSH2.0 ÏÂÁîÐÐÉèÖÃ
FTP¡¢TFTP¡¢XmodemÎļþÉÏÏÂÔØ¹ÜÀí
NTPʱÖÓ
SNMP V1/V2c/V3
RMON
¹ÊÕϺ󱨾¯ºÍ×Ô»Ö¸´
sFLOW

Ó¦ÓÃÓÚ¼«¼òÒÔÌ«²Ê¹âÍøÂç½â¾ö¼Æ»®4.0£¬Ò»Ì¨×°±¸³ÐÔØÇ§¼ä·¿

´îÅä¸ßÃܶȲʹâ°å¿¨¼°³¬¾ÛºÏ²Ê¹âÄ£¿é£¬µ¥¶Ë¿Ú×î¸ßÖ§³Ö160G²Ê¹â´«Ê䣬µ¥Ïß¿¨×î¸ßÖ§³Ö128¸ö·¿¼äÍòÕ×ÈëÊÒ£¬Ïß¿¨ÂúÔØÇéÐÎÏÂ×î¶àÖ§³Ö½ÓÈë1000+·¿¼ä£¬Öª×ã¸ß´ø¿í¡¢¸ßÃܶȳ¡¾°°²ÅÅÐèÇó
1000+
·¿¼ä½ÓÈëÖ§³Ö
100%
½¹µãÃܶȷ­±¶
50%
»ú·¿Õ¼Óÿռ併µÍ

¸ßÃܶÈÔÆ¼Ü¹¹ÍøÂç½¹µã½»Á÷»úRG-N18010-E

Äܹ»Ë³Ó¦²î±ðÍøÂç¹æÄ£µÄ¶Ë¿ÚÃܶȺÍÐÔÄÜÒªÇó£¬ÎªÔƼܹ¹ÍøÂ罨ÉèÌṩÓÐÁ¦µÄ×°±¸°ü¹Ü£¬¿ÉÒÔÆ¾Ö¤ÓªÒµÐèÒª°²ÅÅÔÚÊý¾ÝÖÐÐÄ¡¢³ÇÓòÍø¡¢Ô°ÇøÍø»òÊý¾ÝÖÐÐÄÓëÔ°ÇøÍøÈںϵij¡¾°
¿´°å¿¨
ºóÃæ°å

Õý½»CLOS¼Ü¹¹
ÎÞÛÕ±Õת·¢£¬¸ßËÙ´«Êä²»¶ª°ü

ÓªÒµ°å¿¨Óë½»Á÷Íø°åÍêÈ«Õý½»Éè¼Æ£¬¿ç°å¿¨Á÷Á¿Í¨¹ýÕý½»
ÅþÁ¬Æ÷´«Êäµ½½»Á÷Íø°åÉÏ£¬´«ÊäÏûºÄ½ÏС£¬¼«´ó½µµÍÐźÅ
Ë¥¼õ£¬Ìá¸ßÓªÒµÁ÷Á¿´«ÊäЧÂÊ

ȫеÄÈ«½âñî×é¼þ»¯²Ù×÷ϵͳRGOS£¬¸÷×é¼þÏ໥×ÔÁ¦£¬ÓªÒµÒ»Á¬²»ÖÐÖ¹

ÓªÒµ×é¼þ³¹µ×½âñ×é¼þ¹ÊÕÏÎÞËð×ÔÐÞ¸´£¬È·±£ÏµÍ³µÄ¸ß¿ÉÓÃÐÔ
Ö§³Ö¸÷ÓªÒµ×é¼þµÄ¹¦Ð§ÈÈÉý¼¶£¬ÔÚÏß¹¦Ð§À©Õ¹£¬È·±£ÍøÂç²»ÖÐÖ¹

¸ß¿ÉÓÃÐÔ    

¹ÊÕÏÃë¼¶»Ö¸´

ÈȲ¹¶¡Éý¼¶

CPUÕ¼ÓÃÂʵÍ

Ó²¼þ¼¶¶àÖØ±£»¤£¬µçÐż¶¸ß¿É¿¿£¬¼á³Ö×°±¸Ò»Á¬ÔËÐв»µôÏß

Ó²¼þ¼¶Ë«ÈßÓà
¹â¿Ú¹ÊÕϸôÀë
Ö§³ÖÓ²¼þ²ã¼¶Ë«boot£¬½ÓÄÉÁ½¸öFLASHоƬ´æ´¢bootÈí¼þ£¨ÏµÍ³Ö¸µ¼³ÌÐò£©£¬ÊµÏÖÓ²¼þ¼¶bootÈßÓ౸·Ý£¬×èÖ¹ÒòFLASHоƬ¹ÊÕϵ¼Ö½»Á÷»úÎÞ·¨Æô¶¯

Á¢ÒìµÄµçÉÈ´®ÁªºÍY·çµÀÉè¼Æ£¬É¢Èȸü¸ßЧ£¬ÏµÍ³¿É¿¿ÐÔ¸ü¸ß

´®ÁªµçÉÈÉè¼Æ£¬±È¹Å°åµ¥µçÉÈÐÔÄÜÌáÉý50%£¬·çÁ¦´óÔö£»Ç°¡¢ÓÒ²à½ø·ç£¬ºó³ö·çµÄYÐÍ·çµÀÉè¼Æ£¬ÐγÉ
Á¢ÌåÐÔÉ¢ÈÈͨµÀ£¬É¢Èȸü¸ßЧ£»ÓªÒµ¿¨Óë½»Á÷Íø°å¾ùΪ×ÔÁ¦·çµÀ£¬»¥²»×ÌÈÅ£¬ÏµÍ³¿É¿¿ÐÔ¸ß

RG-UNCÆ½Ì¨ÍøÂçÖÐÐÄ£¬Í³Ò»»¯¼«¼ò¹ÜÀí£¬×Ô¶¯»¯ÇáËÉÔËά

ͳһƽ̨¹ÜÀí£¬ÊµÊ±¼à¿ØÍøÂç״̬£¬Óû§ÌåÑéÈ«Á´¶´²ì¡¢ÖÇÄÜÆÊÎöÕï¶Ï£¬È«·½Î»°ü¹ÜÓªÒµÌåÑé
Ö§³Ö¹âÁ´Â·¶Ëµ½¶ËÔËά£¬¹âÍøÂç¿ÉÊÓ»¯¡¢¿É¹ÜÀí¡¢¿É¿ØÖÆ

ÊÖÒÕ²ÎÊý

Ó²¼þ¹æ¸ñ

ϵͳ¹æ¸ñ RG-N18010-E RG-N18014-E
Ä£¿é²å²Û 10¸ö£¨2¸ö¹ÜÀíÒýÇæÄ£¿é£¬8¸öӪҵģ¿é£©£¬ÁíÍâÖ§³Ö4¸ö×ÔÁ¦½»Á÷Íø°å 14¸ö£¨2¸ö¹ÜÀíÒýÇæÄ£¿é£¬12¸öӪҵģ¿é£©£¬ÁíÍâÖ§³Ö4¸ö×ÔÁ¦½»Á÷Íø°å
½»Á÷Íø°å²Ûλ 4 4
½»Á÷ÈÝÁ¿ 1904Tbps/5752Tbps 2856Tbps/8628Tbps
°üת·¢ËÙÂÊ 460800Mpps 921600Mpps
µçÉÈ¿ò 2 2
³ß´çÓëÖØÁ¿
²úÆ·³ß´ç£¨¿í×Éî׸ߣ© 442.0mm x 561.0mm x 442.5mm (²»º¬×ßÏß¼Ü)
442.0mm x 670.1mm x 442.5mm (º¬×ßÏß¼ÜÓë°ÑÊÖ)
442.0mm x 561.0mm x 605.1mm (²»º¬×ßÏß¼Ü)
442.0mm x 670.1mm x 605.1mm (º¬×ßÏß¼ÜÓë°ÑÊÖ)
»ú¼Ü³ß´ç 10U 14U
µçÔ´Ó빦ºÄ
ϵͳµçÔ´ 4 4
µçÔ´
ÊäÈëµçѹºÍÊä³ö¹¦ÂÊ
RG-PA1600I£º
  • 90~180V£¬¹¦ÂÊ£º1200W

  • 180~264V£¬¹¦ÂÊ£º1600W

RG-PA600I£º
  • 90~180V£¬¹¦ÂÊ£º600W£»

  • 180~264V£¬¹¦ÂÊ£º600W

RG-PD600I£º
  • -40.5V~-75V£¬¹¦ÂÊ£º600W
ÇéÐÎÓë¿É¿¿ÐÔ
MTBF > 200,000Сʱ
ÎÂ¶È ÊÂÇéζȣº0¡æµ½45¡æ
´æ´¢Î¶ȣº-40¡æµ½70¡æ
ʪ¶È ÊÂÇéʪ¶È£º10%µ½90%RH£¨ÎÞÀäÄý£©
´æ´¢Êª¶È£º5%µ½95%RH
ÊÂÇé¸ß¶È/º£°Î -500~5000M

Èí¼þ¹æ¸ñ

Èí¼þ¹æ¸ñ RG-N18010-E RG-N18014-E
×°±¸ÐéÄ⻯ Ö§³ÖVSU(Virtual Switching Unit,ÐéÄâ½»Á÷µ¥Î»)
SDN Ö§³ÖOpenFlow 1.3
L2ÌØÕ÷ Ö§³ÖIEEE 802.3£¨10Base-T£©¡¢802.3u£¨100Base-T£©¡¢IEEE 802.3z£¨1000BASE-X£©¡¢802.3ab£¨1000Base-T£©¡¢IEEE 802.3ae£¨10Gbase£©¡¢IEEE 802.3ba£¨40G/100Gbase£©
Ö§³ÖJumbo Frame
Ö§³ÖSTP¡¢RSTP¡¢MSTP
Ö§³Ö»ùÓڶ˿ڵġ¢Ô´ IPµØÖ·µÄ¡¢Ô´MACµØÖ·µÄ¡¢Ð­ÒéµÄ802.1Q VLAN£¬VLAN IDÊýÄ¿4095¸ö
Ö§³ÖSuper VLAN
Ö§³ÖGVRP
Ö§³ÖQinQ¡¢ÎÞаQinQ¡¢QinQÖսᣨʵÏÖ±âÆ½»¯ÍøÂç¼Ü¹¹£©
Ö§³ÖLLDP
Ö§³ÖERPS£¨G.8032£©
MPLS Ö§³ÖMPLS L3VPN
Ö§³ÖMPLS 6VPE
Ö§³ÖMPLS IPv6
Ö§³ÖVRF
IPv4ÌØÕ÷ Ö§³Ö¾²Ì¬Â·ÓÉ¡¢RIP¡¢OSPFv2¡¢IS-IS¡¢BGP4
Ö§³ÖVRRP
Ö§³ÖµÈ¼Û·ÓÉ
Ö§³ÖÕ½ÂÔ·ÓÉ
Ö§³ÖGREËíµÀ
IPv6ÌØÕ÷ Ö§³Ö¾²Ì¬Â·ÓÉ¡¢RIPng£¬OSPFv3¡¢BGP4+¡¢IS-ISv6¡¢MLDv1/v2
Ö§³ÖVRRPv3
Ö§³ÖµÈ¼Û·ÓÉ
Ö§³ÖÕ½ÂÔ·ÓÉ
Ö§³ÖÊÖ¹¤ËíµÀ¡¢×Ô¶¯ËíµÀ¡¢ISATAPËíµÀ¡¢Ö§³ÖGREËíµÀµÈ
Ö§³ÖPing v6¡¢Telnet v6¡¢FTPv6¡¢TFTPv6¡¢DNSv6¡¢ICMPv6¡¢IPv6 Tracert
×é²¥ Ö§³ÖIGMP v1,v2,v3
Ö§³ÖIGMP Snooping
Ö§³ÖIGMP Proxy
Ö§³ÖPIM-DM¡¢PIM-SM¡¢PIM-SSMµÈ×鲥·ÓÉЭÒé
Ö§³ÖMLD
Ö§³Ö×é²¥¾²Ì¬Â·ÓÉ
VXLAN Ö§³ÖVXLAN¶þ²ãÍø¹Ø
Ö§³ÖVXLAN¶þ²ãÍøÇÅ
Ö§³ÖVXLANÈý²ãÍø¹Ø
Ö§³ÖEVPN VXLAN
×¢£º·Ç¼«¼ò³¡¾°ÏÂÖ§³Ö
ACL Ö§³Ö±ê×¼¡¢À©Õ¹¡¢×¨¼Ò¼¶ACL
Ö§³ÖACL 80
Ö§³ÖIPv6 ACL
QoS Ö§³Ö802.1P
Ö§³ÖSP¡¢WRR¡¢SP+WRRµÈÐÐÁе÷Àí»úÖÆ
Ö§³ÖRED/WRED
Ö§³Ö»ùÓÚ³ö¶Ë¿Ú/Èë¶Ë¿ÚµÄÏÞËÙ
Ö§³ÖDiffserv
Ö§³Ö×Ó½Ó¿ÚQoS
¼¯ÖÐÈÏÖ¤ ´îÅäM18000E-CM IIÖ÷¿ØÒýÇæÊ±£¬×î´óÖ§³Ö10ÍòIPv4ºÍIPv6˫ջÓû§Í¬Ê±ÔÚÏߣ¬Õû»úÈÏÖ¤²¢·¢ÉÏÏßÄÜÁ¦1000ÖÕ¶Ë/ÃëµÄÉÏÏßËÙÂÊ
´îÅäM18000E-CM IIIÖ÷¿ØÒýÇæÊ±£¬×î´óÖ§³Ö30ÍòIPv4ºÍIPv6˫ջÓû§Í¬Ê±ÔÚÏߣ¬Õû»úÈÏÖ¤²¢·¢ÉÏÏßÄÜÁ¦1500ÖÕ¶Ë/ÃëµÄÉÏÏßËÙÂÊ
Ö§³Ö802.1x/Portal/MacµÈ¶àÖÖÈÏÖ¤·½·¨
Ö§³ÖPortalÈÏÖ¤¡¢Ö§³ÖRADIUSºÍTACACS+Óû§µÇ¼ÈÏÖ¤
Ö§³Ö¶þ²ãPortal½ÓÈëÈÏÖ¤
¾µÏñ Ö§³Ö¶à¶ÔÒ»¾µÏñ¡¢Ò»¶Ô¶à¾µÏñ¡¢»ùÓÚÁ÷µÄ¾µÏñ
Ö§³ÖSPAN¡¢RSPANÔ¶³Ì¾µÏñ£¬Ö§³ÖVLANµÄ¾µÏñ
¿É¿¿ÐÔ ×ÔÁ¦µÄ½»Á÷Íø°åÓë×ÔÁ¦µÄÖ÷¿Ø°åÉè¼Æ£¬ÊµÏÖת·¢Óë¿ØÖÆÆ½ÃæÊèÉ¢
Ö÷¿Ø°åÖ§³Ö1+1ÈßÓ౸·Ý
½»Á÷Íø°åÖ§³ÖN+1ÈßÓ౸·Ý
µçÔ´¡¢µçÉÈÖ§³ÖN+MÈßÓ౸·Ý
±³°åÎÞÔ´Éè¼Æ£¬×èÖ¹µ¥µã¹ÊÕÏ
¸÷×é¼þÖ§³ÖÈȲå°Î
Ö§³ÖÈȲ¹¶¡¹¦Ð§£¬¿ÉÔÚÏß¾ÙÐв¹¶¡Éý¼¶
Ö§³ÖIP FRR
Ö§³ÖGR for OSPF/IS-IS/BGP/
Ö§³ÖBFD for VRRP/OSPF/BGP4/ISIS/ISISv6/MPLS/¾²Ì¬Â·ÓɵÈ
Çå¾²ÐÔ Ö§³ÖNFPP£¨»ù´¡Çå¾²±£»¤Õ½ÂÔ£©
Ö§³ÖCPP£¨CPU±£»¤£©
Ö§³ÖDAI£¬¶Ë¿ÚÇå¾²£¬IP Source Guard
Ö§³Ö802.1x
Ö§³ÖPortalÈÏÖ¤¡¢Ö§³ÖRADIUSºÍTACACS+Óû§µÇ¼ÈÏÖ¤
Ö§³ÖuRPF
Ö§³ÖµÇ¼ÈÏÖ¤¡¢¿ÚÁîÇå¾²
Ö§³Öδ֪×é²¥²»ËÍCPU¡¢Ö§³Öδ֪µ¥²¥ÒÖÖÆ
Ö§³ÖSSHv2£¬ÎªÓû§µÇ¼ÌṩÇå¾²¼ÓÃÜͨµÀ
Ö§³ÖIPv6 SAVI
¹ÜÀíÐÔ Ö§³ÖConsole/AUX Modem/Telnet/SSH2.0ÏÂÁîÐÐÉèÖÃ
Ö§³ÖFTP¡¢TFTP¡¢XmodemÎļþÉÏÏÂÔØ¹ÜÀí
Ö§³ÖSNMP V1/V2c/V3
Ö§³ÖRMON
Ö§³ÖNTPʱÖÓ
Ö§³Ö¹ÊÕϺ󱨾¯ºÍ×Ô»Ö¸´
Ö§³ÖϵͳÊÂÇéÈÕÖ¾
Ö§³ÖsFLOWÁ÷Á¿ÆÊÎö
Õö¿ªÏêϸ²ÎÊý

Ó¦ÓôîÅä

160G²Ê¹â
10G¹âÏËÏß
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾

Ó¦Óó¡¾°

¼«¼òÒÔ̫ȫ¹â½â¾ö¼Æ»®3.X

¼«¼òÒÔ̫ȫ¹âÍø3.X¼Æ»®Õë¶Ô½ÌÓý¡¢Ò½ÁÆ¡¢°ì¹«¡¢ÖÇÄÜÖÆÔìµÈÆóÒµ¼¶Ô°ÇøÍø³¡¾°£¬½ÓÄɹâÏËÈëÊÒ°²ÅÅ·½·¨£¬ÈÚºÏÒÔÌ«²Ê¹âÊÖÒÕ£¬ÓÐÓýµµÍÖÐÐÄ»ú·¿µ½¸÷Â¥¶°²¼Ïß±¾Ç®£¬°ü¹Ü´ø¿í¶ÀÏí£¬Ìṩȫ¹âÍø´«Êä¡£½ÓÈë²ã¼¯Öй©µçÉè¼Æ£¬Í¨¹ý²Ê¹â¼¯Öй©µçÊÖÒÕ»ò¹âµçÊèɢʽºãÐÇÖ÷»ú´îÅä¹âµç»ìÏýÀ£¬ÊµÏÖÈõµç¼äÎÞÔ´¡¢³¤¾àÀë¹âÏË´«ÊäÓëPoE¹©µç¡£ÎªÔ°ÇøÍøÓû§´òÔì¸ßЧ¡¢Îȹ̡¢Ò×ÔËάÇÒ¾ßǰհÐÔµÄÈ«¹âÍø¡£

Éó²é¼Æ»®

×ÊÔ´ÖÐÐÄ

ÓªÏú×ÊÁÏ
ÊÖÒÕ²©ÎÄ
ÊÛºóÎĵµ

³£¼ûÎÊÌâ

ÎÒÒªÌáÎÊ
ËùÓÐ
ÃüÃû¹æÔò(1)
µçÉÈ(1)
°å¿¨(1)
»ú¹ñ(1)
×°ÖÃÉî¶È(1)
z**** 2022Äê08ÔÂ10ÈÕ
RG-N18000-EϵÁÐÓа忨֧³Ö100GÂð£¿
ÓÐÓÃ 39 ÎÞÓÃ 5

ÓеÄ£¬100GËÙÂÊµÄ°å¿¨ÍÆ¼öM18000E-12CQ-XB£¬Ò»¹²12¸ö100G¶Ë¿Ú¡£

z**** 2022Äê08ÔÂ10ÈÕ
Õâ¸ö½»Á÷»úÕû»úÉî¶ÈÊǼ¸¶à£¬ÎÒÃÇÏÖÓеĻú¹ñÊÇ800mmµÄÄÜÊÊÓÃÂð£¿
ÓÐÓÃ 58 ÎÞÓÃ 4

RG-N18000-EϵÁн»Á÷»ú»ú¿òÉî¶È¶¼ÔÚ500mmÒÔÏ£¬Éî¶È800mmµÄ»ú¹ñÊÇ¿ÉÒÔÊÊÓõÄ¡£

Õö¿ªËùÓÐ
ÈôÊÇÄúÐèÒª¸ü¶à²úÆ·ÊÖÒÕ×Éѯ
ÏêϸÐÔÄÜÄÜ·ñÖª×ãÄúµÄÓªÒµ·åÖµ£¿ÔõÑùÍýÏë°²ÅÅÓëÉèÖã¿
Á¬Ã¦×Éѯ
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾

·µ»Ø¶¥²¿

ÊÕÆð
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾ ÎĵµAIÖúÊÖ
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾ ÎĵµÆÀ¼Û
¸Ã×ÊÁÏÊÇ·ñ½â¾öÁËÄúµÄÎÊÌ⣿
Äú¶ÔÄ¿½ñÒ³ÃæµÄÖª×ã¶ÈÔõÑù£¿
²»Õ¦µÎ
ºÜÊǺÃ
ÄúÖª×ãµÄÔµ¹ÊÔ­ÓÉÊÇ£¨¶àÑ¡£©£¿
Äú²»Öª×ãµÄÔµ¹ÊÔ­ÓÉÊÇ£¨¶àÑ¡£©£¿
ÄúÊÇ·ñÉÐÓÐÆäËûÎÊÌâ»ò½¨Ò飿
ΪÁË¿ìËÙ½â¾ö²¢»Ø¸´ÄúµÄÎÊÌ⣬Äú¿ÉÒÔÁôÏÂÁªÏµ·½·¨
ÓÊÏä
ÊÖ»úºÅ
ллÄúµÄ·´À¡£¡
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
ÇëÑ¡Ôñ·þÎñÏîÄ¿
¹Ø±Õ×Éѯҳ
ÊÛǰ×Éѯ ÊÛǰ×Éѯ
ÊÛǰ×Éѯ
ÊÛºó·þÎñ ÊÛºó·þÎñ
ÊÛºó·þÎñ
Òâ¼û·´Ïì Òâ¼û·´Ïì
Òâ¼û·´Ïì
¸ü¶àÁªÏµ·½·¨
ÍøÕ¾µØÍ¼