¹¤Òµ¼¶²úÆ·Éè¼Æ
ÎÞ¾åÊÒÍâ±°ÁÓÇéÐΣ¬×°±¸ÎȹÌÔËÐÐ
24¿ÚǧÕ×»ú¼Üʽ¹¤Òµ¼¶ÒÔÌ«Íø½»Á÷»ú RG-IS5200-24GT4XS-UP-DC
ÃæÏòÇå¾²¡¢¸ßЧºÍ½ÚÄܵÄÉè¼ÆÀíÄîÍÆ³öµÄÐÂÒ»´úǧÕ×ÒÔÌ«Íø½»Á÷»ú£¬×¨Îª¹¤ÒµÇéÐÎÉè¼Æ£»»ú¼ÜʽװÖã¬ÇáÓ¯ÎÞа
ÖÐÎÄ
Öª×ãÆéá«Î¡¢¿¹Õñ¶¯¡¢·ÀÀ×»÷µÈÖØ´óÇéÐÎÐèÇó£¬ÊÊÓÃÓÚÊÒÍâ¼à¿Ø¡¢ÌØÊâÌìÆøÌõ¼þºÍÖÆÔìÒµ£¬»¹¿É°²ÅÅÔÚɳĮ¡¢·Û³¾¿ÅÁ£´óµÄÐÂÄÜÔ´¹¤³§¡¢¼°ÑζÇÖÊ´µÄÑØº£µØÇøµÈ³¡¾°
ÀàÐÍ£º
²úÆ·ÌØÕ÷£º
¹¤Òµ¼¶²úÆ·Éè¼Æ
ÎÞ¾åÊÒÍâ±°ÁÓÇéÐΣ¬×°±¸ÎȹÌÔËÐÐ
ÃæÏòÇå¾²¡¢¸ßЧºÍ½ÚÄܵÄÉè¼ÆÀíÄîÍÆ³öµÄÐÂÒ»´úǧÕ×ÒÔÌ«Íø½»Á÷»ú£¬×¨Îª¹¤ÒµÇéÐÎÉè¼Æ£»»ú¼ÜʽװÖã¬ÇáÓ¯ÎÞа
| ½Ó¿Ú¹æ¸ñ | RG-IS5200-8GT4XS | RG-IS5200-8GT4XS-DC | RG-IS5200-8GT4XS-UP-DC | RG-IS5200-24GT4XS-UP-DC |
| ¹Ì»¯ÓªÒµ½Ó¿Ú | 8¸ö10/100/1000BASE-T×Ô˳ӦÒÔÌ«Íø½Ó¿Ú£¬4¸ö1GE/10GE SFP+½Ó¿Ú£¨ÊÚȨºóÖ§³Ö10GE£© | 8¸ö10/100/1000BASE-T×Ô˳ӦÒÔÌ«Íø½Ó¿Ú£¬4¸ö1GE/10GE SFP+½Ó¿Ú£¨ÊÚȨºóÖ§³Ö10GE£© | 8¸ö10/100/1000BASE-T×Ô˳ӦÒÔÌ«Íø½Ó¿Ú£¬Ö§³ÖPoE/PoE+/PoE++£¬4¸ö1GE/10GE SFP+½Ó¿Ú£¨ÊÚȨºóÖ§³Ö10GE£© | 24¸ö10/100/1000BASE-T×Ô˳ӦÒÔÌ«Íø½Ó¿Ú, Ö§³ÖPoE/PoE+/PoE++£¬4¸ö1GE/10GE SFP+½Ó¿Ú£¨ÊÚȨºóÖ§³Ö10GE£© |
| ¹Ì»¯¹ÜÀí½Ó¿Ú | 1¸öRJ45µÄConsole½Ó¿Ú | |||
| RS485½Ó¿Ú | 1¸öRS485½Ó¿Ú£¬Ö§³ÖModbusÐÒé | |||
| DIDO | 1·DI£¬1·DO | |||
| USB½Ó¿Ú | 1¸öUSB 2.0¶Ë¿Ú£¬Ö§³ÖUSBÉèÖÃÖ¸µ¼£¬Ö§³Öͨ¹ýUÅÌÉúÑÄÈÕÖ¾¡¢µ¼³öÉèÖã¬Éý¼¶×°Öðü | |||
ϵͳ¹æ¸ñ
| ϵͳ¹æ¸ñ | RG-IS5200-8GT4XS | RG-IS5200-8GT4XS-DC | RG-IS5200-8GT4XS-UP-DC | RG-IS5200-24GT4XS-UP-DC |
| ½»Á÷ÈÝÁ¿ | 520Gbps/5.2Tbps | |||
| °üת·¢ÂÊ | 102Mpps | 183Mpps | ||
³ß´çÓëÖØÁ¿
| ³ß´çÓëÖØÁ¿ | RG-IS5200-8GT4XS | RG-IS5200-8GT4XS-DC | RG-IS5200-8GT4XS-UP-DC | RG-IS5200-24GT4XS-UP-DC |
| ²úÆ·³ß´ç£¨¿í×Éî׸ߣ© | 150mm×133mm×86mm | 150mm×133mm×86mm | 150mm×133mm×86mm | 442mm×220mm×43.6mm |
| ²úÆ·ÖØÁ¿ | 1.49kg | 1.5kg | 1.53kg | 2.85kg |
| ×°Ö÷½·¨ | ×ÀÃæ×°Öá¢DINµ¼¹ì×°ÖᢱڹÒ×°Öà | ×ÀÃæ×°Öᢻú¼Ü×°ÖᢱڹÒ×°Öà | ||
µçÔ´Ó빦ºÄ
| µçÔ´Ó빦ºÄ | RG-IS5200-8GT4XS | RG-IS5200-8GT4XS-DC | RG-IS5200-8GT4XS-UP-DC | RG-IS5200-24GT4XS-UP-DC | |
| µçÔ´½Ó¿Ú | ·ï»Ë¶Ë×Ó | ||||
| PoE¹©µç±ê×¼ | ²»Ö§³Ö | ½Ó¿Ú1~8Ö§³ÖPoE¡¢PoE+¡¢PoE++£¨IEEE802.3af/at/bt£©¹©µç | ½Ó¿Ú1~24Ö§³ÖPoE¡¢PoE+¡¢PoE++£¨IEEE802.3af/at/bt£©¹©µç | ||
| PoEÊä³ö¹¦ÂÊ | ²»Ö§³Ö | Õû»ú×î´óPoEÊä³ö¹¦ÂÊ£º480W PoE½Ó¿Ú×î´ó¹©µç£º15.4W(PoE)£¬30W(PoE+)£¬60W/90W(PoE++) ˵Ã÷£º RG-IS5200-8GT4XS-UP-DCÉèÖÃIPA240-PµçÔ´×î´óÖ»ÄÜÌṩ210WµÄPoEÊä³ö RG-IS5200-24GT4XS-UP-DCÉèÖÃIPA240-PµçÔ´×î´óÖ»ÄÜÌṩ200WµÄPoEÊä³ö ÏÖʵµÄPoE´øÔØÊýÄ¿£¬ÇëÆ¾Ö¤µçÔ´Ä£¿é¿ÉÓÃ×ܹ¦Âʼ°PoE×°±¸ÏÖʵ¹¦ÂÊÅÌËã¡£ |
|||
| µçÔ´ÊäÈë | ½»Á÷£¨AC£©ÊäÈ룺 ¶î¶¨ÊäÈëµçѹ£º100V~240V AC£¬50/60Hz ×î´óÊäÈëµçѹ£º90V~264V AC£¬50/60Hz ¶î¶¨ÊäÈëµçÁ÷£º0.6A ¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺 ¶î¶¨ÊäÈëµçѹ£º240V DC ×î´óÊäÈëµçѹ£º204V~288V DC ¶î¶¨ÊäÈëµçÁ÷£º0.3A |
˫·±¸·ÝÈßÓàÖ±Á÷£¨DC1/DC2£©ÊäÈ룺 ¶î¶¨ÊäÈëµçѹ£º12V~48V DC ×î´óÊäÈëµçѹ£º9.6V~60V DC ¶î¶¨ÊäÈëµçÁ÷£º2A~0.5A |
˫·±¸·ÝÈßÓàÖ±Á÷£¨DC1/DC2£©ÊäÈ룺 ¶î¶¨ÊäÈëµçѹ£º56V DC ×î´óÊäÈëµçѹ£º54~57V DC£¨Ö§³ÖPoE/PoE+/PoE++£©»ò48V DC£¨½öÖ§³Ö PoE£© ¶î¶¨ÊäÈëµçÁ÷£º10A |
˫·±¸·ÝÈßÓàÖ±Á÷£¨DC1/DC2£©ÊäÈ룺 ¶î¶¨ÊäÈëµçѹ£º12VDC¡¢56V DC ²»Ö§³ÖPoE£º12V DC ½öÖ§³ÖPoE¹©µç£º48V DC Ö§³ÖPoE/PoE+/PoE++¹©µç£º54~57V DC ×î´óÊäÈëµçѹ£º9.6~60V DC ¶î¶¨ÊäÈëµçÁ÷£º10A£¨56Vdc£©¡¢4A£¨12Vdc£© |
|
| Õû»ú×î´ó¹¦ºÄ | 16.8W | 19.8W | 23.8W (ÎÞPoE¸ºÔØ) 503.8W (PoEÂúÔØ) |
12VÖ±Á÷µçÔ´ÊäÈ룺 36.8W 56VÖ±Á÷µçÔ´ÊäÈ룺 35.5W (ÎÞPoE¸ºÔØ) 515.5W (PoEÂúÔØ) |
|
| ÇéÐÎÓë¿É¿¿ÐÔ | RG-IS5200-8GT4XS | RG-IS5200-8GT4XS-DC | RG-IS5200-8GT4XS-UP-DC | RG-IS5200-24GT4XS-UP-DC |
| ·À³¾·ÀˮƷ¼¶ | IP41£¬Í¨¹ýÑ¡ÅäIS52-shield¿ÉÖ§³ÖIP55·À»¤Æ·¼¶ ˵Ã÷£ºÂã»úÏÂIP41·À»¤ÄÜÁ¦ÒªÇóÇ°Ãæ°å¶Ë¿Ú²»ÏòÉÏ×°Öà |
IP40 | ||
| ·ÀÀ× | ACµçÔ´½Ó¿Ú£º¹²Ä£6kV/²îÄ£6kV£¨BÅоݣ© ÓªÒµ½Ó¿Ú£º¹²Ä£10kV/²îÄ£500V(RÅоÝ) |
|||
| ÊÂÇéÎÂ¶È | ÊÂÇéÇéÐÎζȣº(0m¡«1800m º£°Î£¬ÅäÌ×¹¤Òµ¼¶¹âÄ£¿é) –40°C¡«+65°C£¨×°ÖÃÔÚÃÜ·â¹ñ£© –40°C¡«+70°C£¨×°ÖÃÔÚ͸·ç¹ñ£¬Í¸·ç·çËÙÖÁÉÙΪ 80LFM £¨Line Feet Minute£©) –40°C¡«+75°C£¨×°ÖÃÔÚ×Ô´øµçÉȵÄ͸·ç¹ñ£¬Í¸·ç·çËÙÖÁÉÙΪ 200LFM£© ˵Ã÷£ºÔÚº£°Î1800m~5000m¹æÄ£ÄÚ, º£°ÎÿÉý¸ß220m£¬×î¸ßζȹæ¸ñ½µµÍ1¡æ¡£ ´æ´¢ÇéÐÎζȣº–40¡æ~+85¡æ |
ÊÂÇéÇéÐÎζȣº(0m¡«1800m º£°Î£¬ÅäÌ×¹¤Òµ¼¶¹âÄ£¿é) –40°C¡«+60°C£¨×°ÖÃÔÚÃÜ·â¹ñ£¬RG-IS5200-8GT4XS-UP-DCÊä³öPoE¹¦ÂÊ480W£© –40°C¡«+65°C£¨×°ÖÃÔÚÃÜ·â¹ñ£¬ RG-IS5200-8GT4XS-UP-DCÊä³öPoE¹¦ÂÊ210W£¬RG-IS5200-24GT4XS-UP-DC£© –40°C¡«+70°C£¨×°ÖÃÔÚ͸·ç¹ñ£¬Í¸·ç·çËÙÖÁÉÙΪ 80LFM £¨Line Feet Minute£©) –40°C¡«+75°C£¨×°ÖÃÔÚ×Ô´øµçÉȵÄ͸·ç¹ñ£¬Í¸·ç·çËÙÖÁÉÙΪ 200LFM£© ˵Ã÷£ºÔÚº£°Î1800m~5000m¹æÄ£ÄÚ, º£°ÎÿÉý¸ß220m£¬×î¸ßζȹæ¸ñ½µµÍ1¡æ¡£ ´æ´¢ÇéÐÎζȣº–40¡æ~+85¡æ |
||
| ʪ¶È | ÊÂÇéÇéÐÎʪ¶È£º10%RH~90%RH ´æ´¢ÇéÐÎʪ¶È£º5%RH~95%RH |
|||
| º£°Î | ÊÂÇ麣°Î£º0~5000m ´æ´¢º£°Î£º0~5000m |
|||
| ƽ¾ùÎÞ¹ÊÕÏʱ¼ä£¨MTBF£© | 40¡æÒÔÏ´óÓÚ300000Сʱ£¨Ô¼34Ä꣩ | |||
| µçÉÈ | ÎÞµçÉÈ£¬×ÔȻɢÈÈ | |||
| µçÔ´¼à¿Ø | ²»Ö§³Ö | µçÔ´ÔÚλ¼ì²â£ºÖ§³Ö | ||
| ÎÂ¶È¼à¿Ø | Ö§³ÖÎÂ¶È¼à¿Ø¡¢Î¶ȸ澯¡¢¹ýα£»¤ | |||
| ¾²µç¿¹ÈÅ | ±ê×¼²âÊÔ½Ó´¥/¿ÕÆø£º6kV/8kV ÄÍÊÜÐÔ½Ó´¥/¿ÕÆø£º8K/15K |
|||
| ¹¤Æµ´Å³¡ | ÎȹÌÒ»Á¬´Å³¡£º30A/m ¶Ìʱ×÷Óôų¡£º300A/m |
|||
| ´«µ¼¿¹ÈÅ | ÐÔÄÜÅоݣºA ɨƵ¹æÄ££º0.15¡«80MHz µ÷ÖÆ£º80%AM¡¢1kHzÕýÏÒ²¨ ACµçÔ´½Ó¿Ú£º3V ÓªÒµ½Ó¿Ú£º3V DI½Ó¿Ú/DO½Ó¿Ú/RS485½Ó¿Ú £º3V |
ÐÔÄÜÅоݣºA ɨƵ¹æÄ££º0.15¡«80MHz µ÷ÖÆ£º80%AM¡¢1kHzÕýÏÒ²¨ ÊÊÅäÆ÷ACµçÔ´½Ó¿Ú£º3V ÓªÒµ½Ó¿Ú£º3V DI½Ó¿Ú/DO½Ó¿Ú/RS485½Ó¿Ú £º3V |
||
| µçѹµøÂä | ACµçÔ´¿Ú£º ¡ñ Ê£Óàµçѹ70£¥£¬¼á³Ö25ÖÜÆÚ£¨ÅоÝB£© ¡ñ Ê£Óàµçѹ0£¥£¬¼á³Ö0.5ÖÜÆÚ£¨ÅоÝB£© ¡ñ Ê£Óàµçѹ0£¥£¬¼á³Ö1ÖÜÆÚ£¨ÅоÝB£© ¡ñ Ê£Óàµçѹ0£¥£¬¼á³Ö250ÖÜÆÚ£¨ÅоÝC£© |
ÊÊÅäÆ÷ACµçÔ´½Ó¿Ú£º ¡ñ Ê£Óàµçѹ70£¥£¬¼á³Ö25ÖÜÆÚ£¨ÅоÝB£© ¡ñ Ê£Óàµçѹ0£¥£¬¼á³Ö0.5ÖÜÆÚ£¨ÅоÝB£© ¡ñ Ê£Óàµçѹ0£¥£¬¼á³Ö1ÖÜÆÚ£¨ÅоÝB£© ¡ñ Ê£Óàµçѹ0£¥£¬¼á³Ö250ÖÜÆÚ£¨ÅоÝC£© |
||
| г²¨ | ƾ֤IEC61000-3-2£¬GB17625.1£¬Öª×ãAÀà×°±¸ÏÞÖµ | |||
| ÈÏÖ¤Óë¹æÔò | RG-IS5200-8GT4XS | RG-IS5200-8GT4XS-DC | RG-IS5200-8GT4XS-UP-DC | RG-IS5200-24GT4XS-UP-DC |
| EMC¹æÔò | GB 9254-2008, CLASS A | |||
| Èí¼þ¹æ¸ñ | |
| MACµØÖ·±í | Ö§³Ö¾²Ì¬MACµØÖ· Ö§³ÖMACµØÖ·¹ýÂË |
| 802.1Q VLAN | Ö§³Ö4K 802.1Q VLAN Ö§³ÖPort based VLAN Ö§³ÖMAC based VLAN Ö§³ÖProtocol based VLAN Ö§³ÖPrivate VLAN Ö§³ÖVoice VLAN Ö§³ÖIP subnet-based VLAN Ö§³ÖGVRP |
| QinQ | Ö§³Ö»ù±¾QinQ Ö§³ÖÎÞаQinQ |
| ¶þ²ã»·ÍøÊÖÒÕ | Ö§³ÖG.8032¹ú¼Ê±ê×¼»·ÍøÐÒéERPS£¬¿ÉÓëÆäËûÖ§³Ö¸ÃÐÒéµÄ²úÆ·¼æÈÝ Ö§³ÖSTP Ö§³ÖRSTP Ö§³ÖMSTP |
| ¶Ë¿Ú¾ÛºÏ | Ö§³ÖÁ÷Á¿Æ½ºâ·½·¨ Ö§³ÖLACP¾²Ì¬¡¢¶¯Ì¬¾ÛºÏ Ö§³Ö¿çVSU AP |
| Mirror | Ö§³ÖͨË×ÓªÒµ¿Ú¡¢¾ÛºÏ¶Ë¿Ú×÷Ϊ¾µÏñµÄÔ´ÒÔ¼°Ä¿µÄ¶Ë¿Ú Ö§³Ö»ùÓÚÁ÷¡¢»ùÓÚVLANµÄ¶Ë¿Ú¾µÏñ Ö§³ÖÒ»¶ÔÒ»¡¢¶à¶ÔÒ»¡¢·´Éä¿ÚÒ»¶Ô¶àµÄ¾µÏñ£¬Ö§³ÖRSPAN Ö§³Ö¿ç×°±¸µÄÁ÷Á¿¾µÏñ |
| DHCP | Ö§³ÖDHCP Server Ö§³ÖDHCP Client Ö§³ÖDHCP Snooping Ö§³ÖDHCP Relay Ö§³ÖIPv6 DHCP Snooping Ö§³ÖIPv6 DHCP Client Ö§³ÖIPv6 DHCP Relay |
| VSUÌØÕ÷ | Ö§³ÖVSUÐéÄ⻯ÊÖÒÕ Ö§³ÖÍâµØ¶ÑµþºÍÔ¶³Ì¶Ñµþ Ö§³Öͨ¹ý±ê×¼ÓªÒµ¿ÚʵÏÖÐéÄ⻯ |
| ÁãÉèÖà | Ö§³ÖCWMP(TR069)ÐÒé±ê×¼ÐÒé |
| IP·ÓÉ | IPv4/IPv6 ¾²Ì¬Â·ÓÉ RIP¡¢RIPng¡¢OSPFv2¡¢OSPFv3 Routing Policy |
| ACL | Ö§³Ö±ê×¼IP ACL Ö§³ÖÀ©Õ¹IP ACL Ö§³ÖMACÀ©Õ¹ACL Ö§³Ö»ùÓÚʱ¼äACL Ö§³Öר¼Ò¼¶ACL Ö§³ÖACL80 Ö§³ÖIPv6 ACL Ö§³ÖÈ«¾ÖACL Ö§³ÖACLÖØ¶¨Ïò |
| IPv6»ù´¡ÐÒé | IPv6±àÖ·¡¢ÁÚÈË·¢Ã÷ÐÒ飨ND£©¡¢ICMPv6¡¢IPv6 Ping¡¢IPv6 TracertµÈ |
| QoS | Ö§³Ö¶Ë¿ÚÁ÷Á¿ÏÞËÙ Ö§³Ö802.1p/DSCP/ IP precedenceÁ÷Á¿·ÖÀà ÿ¶Ë¿Ú8¸öÓÅÏȼ¶ÐÐÁÐ Ö§³ÖSP¡¢WRR¡¢DRR¡¢SP+WFQ¡¢SP+WRR¡¢SP+DRRÐÐÁе÷Àí |
| Çå¾²ÌØÕ÷ | Ö§³Ö»ùÓڶ˿ںÍMACµÄ802.1x Ö§³ÖMAB Ö§³ÖPortal ºÍPortal 2.0ÈÏÖ¤ Ö§³ÖARP Check Ö§³ÖDAI Ö§³Ö·ÀÍø¹ØARPÓÕÆ Ö§³Ö¹ã²¥·ç±©ÒÖÖÆ ¹ÜÀíÔ±·Ö¼¶¹ÜÀíºÍ¿ÚÁî±£»¤ Ö§³ÖRADIUS ºÍ TACACS+ Ö§³ÖBPDU Guard Ö§³ÖIP Source Guard Ö§³ÖCPP¡¢NFPP Ö§³Ö¶Ë¿Ú±£»¤ |
| ¹ÜÀíÌØÕ÷ | SNMP¡¢CLI(Telnet/Console)¡¢RMON(1£¬2£¬3£¬9)¡¢SSH¡¢Syslog/Debug¡¢NTP/SNTP¡¢FTP¡¢TFTP¡¢Web¡¢sFLOW |